Lincat CG6nFL [4/12] Check list of enclosures
![Lincat CG4pFL [4/12] Check list of enclosures](/views2/1337479/page4/bg4.png)
IS205 ECN3592
4
TECHNICAL DATA
Model
CG4
CG6
Dimensions
Overall height (mm)
415
415
Width (mm)
450
600
Depth (mm)
660
660
Weight (kg)
27kg (Nett)
35kg (Nett)
Hob cooking surface w x d (mm)
325 x 440
475 x 440
Heat Input
Total heat input Natural(Gross)
14.3 kW
14.3 kW
Total heat input Propane(Gross)
14.5 kW
14.5 kW
Connection and Operating Pressures
Gas inlet connection
½” BSPT Male
Supply Pressure - Natural
20mbar
20mbar
Operating Pressure - Natural
16.0 mbar
16.0 mbar
Supply Pressure - Propane
37mbar
37mbar
Operating Pressure - Propane
25.0 mbar
25.0 mbar
Gas Consumption
Total gas rate – Natural
1.36 m
3
h
-1
1.36 m
3
h
-1
Total gas rate – Propane
1.04 kg h
-1
1.04 kg h
-1
COMMISSIONING
PREPARATION
Remove all packaging and protective coatings prior to installation.
Check that the heat transfer channels have been fitted correctly.
VENTILATION
The area in which this equipment is to be installed should have sufficient fixed ventilation to comply
with local legislation requirements. It is recommended that a room, or internal space, be provided
with a minimum free area of 4.5cm
2
per kW (3,400Btu/hr) of total heat input.
CHECK LIST OF ENCLOSURES
Please ensure the following items are included with this piece of equipment:
Model
CG4 / CG6
Tick
Warranty Card
1
Pressure Governor
1
Coooking Grid
1
Instruction Manual
1
Содержание
- Silverlink 600 gas chargrills cg4 and cg6 1
- User installation and servicing instructions 1
- Important information 2
- Caution 3
- Contents 3
- Contents page 3
- It is mandatory that all appliances are installed commissioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installation failure to comply will invalidate the warranty 3
- Warning 3
- Warnings and precautions 3
- Check list of enclosures 4
- Commissioning 4
- Technical data 4
- Installation 5
- Serial number 5
- User instruction 6
- Servicing 7
- Component replacement 8
- Burner bu28 9
- Burner s will not light or stay lit 9
- Control knob kn184 9
- Cooking grid handle ha50 9
- Copper washer co113 9
- Fault finding 9
- Fibre washer wa08 9
- Foot fe37 9
- Gas valve va09 9
- Injector 9
- Injector natural gas je28 9
- Injector propane gas je45 9
- Locknut co53 9
- Male stud elbow co85 9
- Pressure governor pg10 9
- Remove the control knobs and fascia panel loosen the burner pipe nut jj at the valve ff and at the elbow ll remove the screws at the elbow retaining bracket kk remove the injector mm with the copper and fibre washers fit new parts and re assemble perform gas soundness test of circuit prior to operation of appliance 9
- Spare parts list 9
- Thermocouple tc14 9
- 44 0 1522 875520 10
- Lincat service help desk 10
- Service information 10
Похожие устройства
- Lincat CG6nFL Каталог оборудования Lincat (англ.)
- Lincat D6R/100S Инструкция по эксплуатации
- Lincat D6R/100S Каталог оборудования Lincat (англ.)
- Lincat DF4nFL Инструкция по эксплуатации
- Lincat DF4nFL Каталог оборудования Lincat (англ.)
- Lincat D5R/125B Инструкция по эксплуатации
- Lincat D5R/125B Каталог оборудования Lincat (англ.)
- Lincat DF4pFL Инструкция по эксплуатации
- Lincat DF4pFL Каталог оборудования Lincat (англ.)
- Lincat D5R/100B Инструкция по эксплуатации
- Lincat D5R/100B Каталог оборудования Lincat (англ.)
- Lincat CG6pFL Инструкция по эксплуатации
- Lincat CG6pFL Каталог оборудования Lincat (англ.)
- Lincat DF39FL Инструкция по эксплуатации
- Lincat DF39FL Каталог оборудования Lincat (англ.)
- Lincat DF618FL Инструкция по эксплуатации
- Lincat DF618FL Каталог оборудования Lincat (англ.)
- Lincat DF7pFL Инструкция по эксплуатации
- Lincat DF7pFL Каталог оборудования Lincat (англ.)
- Lincat C6H/100S Инструкция по эксплуатации