Lincat CG6nFL [4/12] Check list of enclosures

Lincat CG4pFL [4/12] Check list of enclosures
IS205 ECN3592
4
TECHNICAL DATA
Model
CG4
CG6
Dimensions
Overall height (mm)
415
415
Width (mm)
450
600
Depth (mm)
660
660
Weight (kg)
27kg (Nett)
35kg (Nett)
Hob cooking surface w x d (mm)
325 x 440
475 x 440
Heat Input
Total heat input Natural(Gross)
14.3 kW
14.3 kW
Total heat input Propane(Gross)
14.5 kW
14.5 kW
Connection and Operating Pressures
Gas inlet connection
½” BSPT Male
Supply Pressure - Natural
20mbar
20mbar
Operating Pressure - Natural
16.0 mbar
16.0 mbar
Supply Pressure - Propane
37mbar
37mbar
Operating Pressure - Propane
25.0 mbar
25.0 mbar
Gas Consumption
Total gas rate Natural
1.36 m
3
h
-1
1.36 m
3
h
-1
Total gas rate Propane
1.04 kg h
-1
1.04 kg h
-1
COMMISSIONING
PREPARATION
Remove all packaging and protective coatings prior to installation.
Check that the heat transfer channels have been fitted correctly.
VENTILATION
The area in which this equipment is to be installed should have sufficient fixed ventilation to comply
with local legislation requirements. It is recommended that a room, or internal space, be provided
with a minimum free area of 4.5cm
2
per kW (3,400Btu/hr) of total heat input.
CHECK LIST OF ENCLOSURES
Please ensure the following items are included with this piece of equipment:
Model
Tick
Warranty Card
Pressure Governor
Coooking Grid
Instruction Manual
Скачать