Bypass Injector Adjustment
Remove the control knobs
Adjustment for conversion from Natural gas
to Propane or Butane:
Rotate the bypass injector clockwise full
home, do not over tighten.
Replace the control knobs
Adjustment for conversion from Propane or
Butane to Natural gas :
Ensure the bypass injector is fully home, do
not over tighten
Rotate the bypass injector between 1/3 to
1/2 of a turn anticlockwise
Replace the control knobs
Fig 4
Содержание
- Installation operating servicing and conversion instructions silverlink 600 gas boiling tops ht3 ht6 ht9 p.1
- Keep this manual for future reference p.2
- Important information p.2
- Contents p.2
- Warnings and precautions p.3
- Supply pressure natural p.4
- Depth mm p.4
- Supply pressure butane p.4
- Butane p.4
- Propane p.4
- Overall height mm p.4
- Natural p.4
- Individual burner heat input low rate p.4
- Width mm p.4
- Individual burner heat input full rate p.4
- Weight kg p.4
- Individual burner gas consumption low rate p.4
- Total heat input propane gross p.4
- Individual burner gas consumption full rate p.4
- Total heat input natural gross p.4
- Ht3 ht6 ht9 p.4
- Total heat input butane gross p.4
- Gas rate propane p.4
- Total gas rate propane p.4
- Gas rate natural p.4
- Total gas rate natural p.4
- Gas rate butane p.4
- Total gas rate butane p.4
- Gas inlet connection p.4
- Technical data p.4
- Gas consumption low rate p.4
- Supply pressure propane p.4
- Gas consumption full rate p.4
- Check list of enclosures p.5
- Installation and commissioning p.6
- Operating instructions p.8
- Cleaning p.9
- Servicing maintenance and component replacement p.10
- Conversion p.11
- Turn on gas supply or interlock switch p.13
- Tighten connection replace thermocouple ok p.13
- Replace valve p.13
- Fault finding p.13
- Check thermocouple mv output check thermocouple connection p.13
- Check supply pressure p.13
- Check burner ports for blockages clean burner ports p.13
- Call service agent ok p.13
- Call service agent p.13
- Burner not lighting p.13
- Burner lights but will not remain lit p.13
- Burner lights but not all ports are lit p.13
- Spare parts list p.14
- Accessories p.15
- Service information p.16
Похожие устройства
-
Lincat HT9pFLКаталог оборудования Lincat (англ.) -
Lincat HT9pFLИнструкция по эксплуатации -
Lincat HT6pFLКаталог оборудования Lincat (англ.) -
Lincat HT6pFLИнструкция по эксплуатации -
Lincat HT6nFLКаталог оборудования Lincat (англ.) -
Lincat HT6nFLИнструкция по эксплуатации -
Lincat HT3/pКаталог оборудования Lincat (англ.) -
KRAFT KF-FSK6403AGWЭксплуатационная инструкция -
KRAFT KF-FSK5403AGBRИнструкция по применению -
KRAFT KF-FSK5404AGWGЭксплуатационная инструкция -
KRAFT KF-FSK5403AGWИнструкция к устройству -
KRAFT KF-FSK5401AGWРуководство по использованию
Узнайте, как правильно настроить инжектор для конверсии между природным газом, пропаном и бутаном. Подробные инструкции по регулировке и замене ручек управления.