Lincat HT3/p [11/16] Conversion
![Lincat HT6pFL [11/16] Conversion](/views2/1337678/page11/bgb.png)
IS 513 ECN 3706 Page 11 of 16
CONVERSION OF GAS TYPE
Burner Injector Changes
Model Gas
Inlet
Pressure
∅
∅∅
∅
Mark
Part
Number
All
G20 20mbar 1.64 164 JE155
G30 28-30mbar 0.98 98 JE157
G31 37mbar 1.10 110 JE156
Conversion from One Gas Type to Another
To convert the appliance from one gas type to another it will be necessary to replace the
main burner injectors
Ensure the appliance for conversion and all its parts are in a 'cold' state
Remove the pan support(s) for ease of access
Remove the burner caps and burner heads
Remove and replace the burner injectors as detailed below applicable to the gas type
required.
Replace gas specific labels for which the appliance has been converted
Replace data plate corresponding to gas type
Burner Injector
The burner injector is fitted to the base of
the burner body
Remove the burner cap 'BU09'
Remove the burner head 'BU08
Access to the burner injector 'JExx' is
through the venturi to the base of the burner
body 'BU07'. To remove un-screw by
turning anticlockwise
The correct size of the injector appertaining
to gas type is marked on one of the
hexagonal faces of the injector.
Replace with the correct injector applicable
to gas type and reassemble burner parts
CONVERSION
BU09
BU08
JExx
BU07
Fig 3
Содержание
- Installation operating servicing and conversion instructions silverlink 600 gas boiling tops ht3 ht6 ht9 1
- Contents 2
- Important information 2
- Keep this manual for future reference 2
- Warnings and precautions 3
- Butane 4
- Depth mm 4
- Gas consumption full rate 4
- Gas consumption low rate 4
- Gas inlet connection 4
- Gas rate butane 4
- Gas rate natural 4
- Gas rate propane 4
- Ht3 ht6 ht9 4
- Individual burner gas consumption full rate 4
- Individual burner gas consumption low rate 4
- Individual burner heat input full rate 4
- Individual burner heat input low rate 4
- Natural 4
- Overall height mm 4
- Propane 4
- Supply pressure butane 4
- Supply pressure natural 4
- Supply pressure propane 4
- Technical data 4
- Total gas rate butane 4
- Total gas rate natural 4
- Total gas rate propane 4
- Total heat input butane gross 4
- Total heat input natural gross 4
- Total heat input propane gross 4
- Weight kg 4
- Width mm 4
- Check list of enclosures 5
- Installation and commissioning 6
- Operating instructions 8
- Cleaning 9
- Servicing maintenance and component replacement 10
- Conversion 11
- Burner lights but not all ports are lit 13
- Burner lights but will not remain lit 13
- Burner not lighting 13
- Call service agent 13
- Call service agent ok 13
- Check burner ports for blockages clean burner ports 13
- Check supply pressure 13
- Check thermocouple mv output check thermocouple connection 13
- Fault finding 13
- Replace valve 13
- Tighten connection replace thermocouple ok 13
- Turn on gas supply or interlock switch 13
- Spare parts list 14
- Accessories 15
- Service information 16
Похожие устройства
- Lincat HT3/p Каталог оборудования Lincat (англ.)
- Lincat HT6nFL Инструкция по эксплуатации
- Lincat HT6nFL Каталог оборудования Lincat (англ.)
- Lincat HT6pFL Инструкция по эксплуатации
- Lincat HT6pFL Каталог оборудования Lincat (англ.)
- Бирюса 146 Руководство пользователя
- Rock Kitchen HM-22A Инструкция по эксплуатации
- Rock Kitchen HM-22A Каталог Rock Kitchen HHD-05
- Rock Kitchen HM-22B Инструкция по эксплуатации
- Rock Kitchen HM-22B Каталог Rock Kitchen HHD-05
- Lincat HT7FL Инструкция по эксплуатации
- Lincat HT7FL Каталог оборудования Lincat (англ.)
- Lincat HT9pFL Инструкция по эксплуатации
- Lincat HT9pFL Каталог оборудования Lincat (англ.)
- Lincat J10pFL Инструкция по эксплуатации
- Lincat J10pFL Каталог оборудования Lincat (англ.)
- Lincat J10nFL Инструкция по эксплуатации
- Lincat J10nFL Каталог оборудования Lincat (англ.)
- Lincat J5nFL Инструкция по эксплуатации
- Lincat J5nFL Каталог оборудования Lincat (англ.)