Lincat HT3/p [11/16] Conversion

Lincat HT6pFL [11/16] Conversion
IS 513 ECN 3706 Page 11 of 16
CONVERSION OF GAS TYPE
Burner Injector Changes
Model Gas
Inlet
Pressure
Mark
Part
Number
All
G20 20mbar 1.64 164 JE155
G30 28-30mbar 0.98 98 JE157
G31 37mbar 1.10 110 JE156
Conversion from One Gas Type to Another
To convert the appliance from one gas type to another it will be necessary to replace the
main burner injectors
Ensure the appliance for conversion and all its parts are in a 'cold' state
Remove the pan support(s) for ease of access
Remove the burner caps and burner heads
Remove and replace the burner injectors as detailed below applicable to the gas type
required.
Replace gas specific labels for which the appliance has been converted
Replace data plate corresponding to gas type
Burner Injector
The burner injector is fitted to the base of
the burner body
Remove the burner cap 'BU09'
Remove the burner head 'BU08
Access to the burner injector 'JExx' is
through the venturi to the base of the burner
body 'BU07'. To remove un-screw by
turning anticlockwise
The correct size of the injector appertaining
to gas type is marked on one of the
hexagonal faces of the injector.
Replace with the correct injector applicable
to gas type and reassemble burner parts
CONVERSION
BU09
BU08
JExx
BU07
Fig 3

Содержание