Beko CSG 52110 GW [12/96] J installation

Содержание

J Installation It can be used with cabinets on either side but in order to have a minimum distance of 400mm above hotplate level allow a side clearance of 65mm between the appliance and any wall partition or tall cupboard It can also be used in a free standing position Allow a minimum distance of 750 Preparation of location and electrical and mm above the hob surface gas installation for the product is under If a cooker hood is to be installed above customer s responsibility the cooker refer to cooker hood A DANGER manufacturer instructions regarding The product must be installed in installation height min 650 mm 1 Accordance with all local gas and or The appliance corresponds to device class 1 electrical regulations i e it may be placed with the rear and one DANGER side to kitchen walls kitchen furniture or Prior to installation visually check if the equipment of any size The kitchen furniture product has any defects on it If so do or equipment on the other side may only be not have it installed of the same size or smaller Damaged products cause risks for your Any kitchen furniture next to the appliance safety must be heat resistant 100 C min Product must be installed by a qualified person in accordance with the regulations in force The manufacturer shall not be held responsible for damages arising from procedures carried out by unauthorized persons which may also void the warranty m B Before installation Room ventilation To ensure that critical air gaps are maintained under the appliance we recommend that this appliance is mounted on a solid base and that the feet do not sink into any carpet or soft flooring The kitchen floor must be able to carry the weight of the appliance plus the additional weight of cookware and bakeware and food All rooms require an openable window or equvalent and some rooms will require a permanent vent as well The air for combustion is taken from the room air and the exhaust gases are emitted directly into the room Good room ventilation is essential for safe operation of your appliance If there is no window or door available for room ventilation an extra ventilation must be installed The appliance may be located in a kitchen kitchen diner or a bed sitting room but not in a room containing a bath or shower The appliance must not be installed in a bed sitting room of less than 20m3 Do not install this appliance in a room below ground level unless it is open to ground level on at least one side 12 EN Room size Ventilation opening smaller than 5 m15 5 m3 to 10 m3 greater than 10 m den In the cellar or basement mln 100 cm min 50 cm not required min 65 cm