Weissgauff HV 312 B [4/20] Protection against unintentional activation
After setting cooking stage “9“ Automatic parboiling is activated
by pressing at the right slider sensor. “A” appears on the display
imm ediately.
Now the required onboiling stage is selected via Slider area. The
“A” symbol appears after 3 sec. upon releasing the key -
alternating with the onboiling stage (500 msec. “A” and 1.5 sec.
onboiling stage).
The onboiling stage may be changed within 15 sec after
activation w ithout switching off the parboiling boost. Therefore,
the cooking zone is to be selected and the relevant cooking zone
is to be set afterw ards.
In case of a selection after 15 sec a lower cooking stage m ay be
set; automatic onboiling is switched off.
a higher onboiling stage may be selected; this leads to the
parboiling time being automatically brought in line with the
currently selected onboiling stage
Multi Circuit Activation (Optional)
The control unit may trigger – depending on the type – dual circuit
or triple circuit. M ulti Circuits are switched autom atically on after
activating a cooking zone.
Activation/Deactivation of dual circuit HL
By actuating the dual-circuit key “3” the respective double or
outer circuit is deactivated. Re-actuating the dual-circuit key “3”
activates the outer circuit again,
An active double or outer circuit is also shown by the assigned
LED “11” is statically illuminated.
Activation/Deactivation of triple circuit HL
For triple-circuit the following operation procedure is provided:
-By actuating the multi-circuit key “3” the respective double and
triple circuits of an active cooking z one are deactivated.
-Re-actuating the multi circuit key “3” activates the first outer
circuit and the assigned LED “11” illuminates again.
-A second actuation of the multi circuit key “3” activates the
second outer circuit and the assigned LE D “11” illuminates again.
Residual Heat
The determination of how long a cooking zone has residual heat
after operation and switch off – which may lead to burnings when
contacting – is calculated.
Status is calculated depending on:
Selected power stage (from “0” to “9”)
On/Off Time of the Relays
The residual heat indication of each cooking zone remains
activated until the calculated tem perature is smaller than + 60 °C.
Automatic Switch-off (Operating Time Limitation)
For each activated cooking zone a max. operating time is
defined. The max. operating time is depending on the selected
cooking stage. After the expiration of the max. operating time the
cooking zone is automatically switched off.
Each actuation of the cooking zone status (changing the cooking
level etc.) resets the count-down timer to the initial starting value.
Timer settings take priority vs. operating time limitations for high
cooking stage setting.
Protection against unintentional activation
The electronic system cuts off automatically in case of an
identified permanent use of keys for about 10 seconds. The
control unit releases an audible signal for 10 sec of the
malfunction (period: 1000 msec., 500 m sec. ON) and the error
code “E R 0 3” flashes on the display (0.5 s ON 0.5s OFF). If the
permanent actuation exceeds 10 sec., only the error code “ER
03“ keeps flashing as long as the m alfunction occurs and is
identified as such. In case the cooking zone is at stage “hot“ the
[H] symbol alternates with the error code (0.5 sec Symbol 0.5 sec
“H“).
Water sprinkled on the glass surface does not always lead to a
key actuation and cannot be surely detected. ( After wiping the
glass covering the keys, all keys are ready for operation in no
time).
If no cooking zone is activated within 20 sec after pressing
POWER ON, the control unit is reset to Off-mode (black displays).
Key Lock (Optional)
The actuation of the key lock key “4” in the w ait or active mode
locks the keyboard and the assigned key-lock LED “7” is
statically illuminated. Here, the actuation times of the key-lock
key have to be taken into account. The control continues to work
in the set mode, but may no longer be operated with any key,
except the key-lock key itself or the on/off key “1”.
The switching O FF with the on/off key “1” is also possible in the
locked condition. The assigned key-lock LED “7” fades when
switching off the control The key-lock function included LED is
active again when sw itching on (in wait mode 10 s) until this is
deactivated by a repeated actuation of the key-lock key. The
activation/deactivation of the key-lock function in the off mode is
not possible.
When programmed timers expire, the respective timer alarms
may be confirmed by actuating any key w ithout needing to unlock
the control.
The repeated actuation of the key-lock key in the wait or active
mode unlocks the keyboard and the assigned key-lock LED
fades. All sensor keys may be operated as usual again.
Acoustic Feedback (Buzzer)
The following activities occurring during operation of the TC unit
are fed back audibly via a buzzer:
Short single tone for regular actuation of a key
Longer, intermittent tone for permanent use of keys over a longer
period of time (≥ 10 sec)
Expiry of the timer
Timer-function (optional)
The timer function is available in two types:
-Stand-alone-timer 1..99 min: Audible signal with timing. This
function can only be activated as long as no cooking zone is in
operation (all stages = 0). Is any cooking zone started with
operation (level > 0) than the stand alone timer keeps in operation.
If the timer shall be used to cut off a cooking zone (see cooking
zone timer) then the control must first be sw itched off (power
sensor) and switched on again.
Содержание
- Automatic parboiling selectable 3
- Automatic switch off 3
- Functionality slider tc 3
- Installation 3
- On off cooking zone 3
- On off touch control 3
- Power stages 3
- User s instructions fig 1 3
- Acoustic feedback buzzer 4
- Automatic switch off operating time limitation 4
- Key lock optional 4
- Multi circuit activation optional 4
- Protection against unintentional activation 4
- Residual heat 4
- Timer function optional 4
- Activating the pause function 5
- During the pause 5
- Pause mode 5
- Terminating the pause mode 5
- Electrical connection fig 5 6
- Installation 6
- Installer s instructions 6
- Maintenance fig 3 6
- Positioning fig 4 6
- Precautions fig 2 6
- Settings recovery 6
- Arbeitsweise abb 1 11
- Automatisches ausschalten 11
- Automatisches hochkochen mit auswahl 11
- Ein aus der kochzonen 11
- Fingerdrucksteuerung ein aus 11
- Funktionsweise des slider tc 11
- Installation 11
- Leistungsstufen 11
- Akustische meldungen pieper 12
- Automatisches ausschalten betriebszeitbegrenzung 12
- Mehrfachkreis aktivierung 12
- Resthitze 12
- Schutz gegen ungewolltes einschalten 12
- Tastenblockierung optional 12
- Timer funktion optional 12
- Aktivierung der betriebsweise pause 13
- Betriebsweise pause 13
- Deaktivierung der betriebsweise pause 13
- Einstellungen wiederherstellen 13
- Während der pause 13
- Anweisungen für den installateur installation 14
- Aufstellung abb 4 14
- Elektrischer anschluß abb 5 14
- Falls das netzkabel beschädigt ist muss es durch den hersteller oder seinen technischen kundendienst oder in jedem fall durch eine entsprechend qualifizierte fachkraft ersetzt werden um jedes risiko auszuschließen 14
- Instandhaltung abb 3 14
- Vorsichtsmaßnahmen abb 2 14
- Fig рис 3 abb 16
- Fig рис 4 abb 16
- Info weissgauff ru 20
Похожие устройства
- Thermex System 1000 (wh) Инструкция по эксплуатации
- Bosch KGN39VL15R Silver Инструкция по эксплуатации
- Supra HBS-831 WHITE Инструкция по эксплуатации
- Supra CGS-310 Черный Инструкция по эксплуатации
- Bosch KGN39NW13R White Инструкция по эксплуатации
- Supra KES-1835W СЕРЕБРИСТЫЙ Руководство по эксплуатации
- LG GC-M40BSCVM Серебристый Инструкция по эксплуатации
- Supra CGS-310 Коричневый Инструкция по эксплуатации
- Supra MXS-201 IVORY Инструкция по эксплуатации
- Supra HS-201 BLACK Инструкция по эксплуатации
- Supra MTS-221 ЧЕРНЫЙ Руководство по эксплуатации
- Supra JES-1850 Инструкция по эксплуатации
- Supra mTS-320N Инструкция по эксплуатации
- Supra HS-201 WHITE Инструкция по эксплуатации
- Scarlett SC-BS33M041 Разноцветный Инструкция по эксплуатации
- Supra mTS-322 Инструкция по эксплуатации
- Supra KES-1723 WHITE/YELLOW Инструкция по эксплуатации
- Scarlett SC - JE50S08 Инструкция по эксплуатации
- Scarlett Disney SC-BSD33E891 Красный Инструкция по эксплуатации
- Scarlett SC - JE50S11 Инструкция по эксплуатации
Скачать
Случайные обсуждения
Ответы 0
Здравствуйте, не работают оба круга большой конфорки. В чем причина? Малая работает.
3 года назад