Braun TS745A 0X12711022 [11/80] H decalcifying anticalc system

Braun TS745A 0X12711022 [11/80] H decalcifying anticalc system
11
a minimum of 30 minutes. Brush off
remaining residues and rinse under
running water (fi g. G, 1-7).
Re-inserting the steam regulator
When re-inserting the steam regulator,
make sure the steam regulator base still
points on setting x (fi g. G 8). Firmly push
down the steam regulator until it turns
back to setting «6» (fi g. G) where it
catches.
Notice: The iron must never be used
without steam regulator.
H Decalcifying/anticalc system
In order to clean the steam chamber from
residues, decalcify it as shown in picture
section H, 1-8.
Caution: Hot water and steam will come
out from the sole plate when the steam
regulator is turned clockwise beyond
setting «6».
Wait for the sole plate to cool down, then
clean it as described above. Then refi ll the
tank with water, heat up the iron and press
the precision shot button 4 times to rinse
the iron before ironing (fi g. H, 9-13).
Do not use commercial decalcifi ers, they
may damage the iron.
Trouble-shooting guide
Problem Remedy
Drops coming out
of the steam vents.
Turn the steam regulator
anti-clockwise to reduce
the steam or turn it off.
Take longer intervals
when pressing the
Precision Shot button.
Select a higher
temperature setting.
Less steam
develops or no
steam at all.
Check water level.
Clean the anticalc valve.
Calcium particles
coming through
the steam vents.
Decalcify the steam
chamber.
Subject to change without notice.
Please do not dispose of the product
in the household waste at the end of its
useful life. Disposal can take place at a
Braun Service Centre or at appropriate
collection points provided in your country.
5712710084_TS_745-715_S06-80.indd 115712710084_TS_745-715_S06-80.indd 11 18.11.13 08:2818.11.13 08:28

Содержание

Похожие устройства

a minimum of 30 minutes Brush off remaining residues and rinse under running water fig G 1 7 Re in setting the steam regulator When re inserting the steam regulator make sure the steam regulator base still points on setting fig G 8 Firmly push down the steam regulator until it turns back to setting 6 fig G where it catches Notice The iron must never be used without steam regulator H Decalcifying anticalc system In order to clean the steam chamber from residues decalcify it as shown in picture section H 1 8 Caution Hot water and steam will come out from the sole plate when the steam regulator is turned clockwise beyond setting 6 Wait for the sole plate to cool down then clean it as described above Then refill the tank with water heat up the iron and press the precision shot button 4 times to rinse the iron before ironing fig H 9 13 Do not use commercial decalcifiers they may damage the iron Trouble shooting guide Problem Remedy Drops coming out of the steam vents Turn the steam regulator anti clockwise to reduce the steam or turn it off Take longer intervals when pressing the Precision Shot button Select a higher temperature setting Less steam develops or no steam at all Check water level Clean the anticalc valve Calcium particles coming through the steam vents Decalcify the steam chamber Subject to change without notice Please do not dispose of the product in the household waste at the end of its useful life Disposal can take place at a Braun Service Centre or at appropriate collection points provided in your country 11 5712710084 TS 745 715 S06 80 indd 11 18 11 13 08 28

Скачать