1. USER MAINTENANCE
Operates once a month the discharge of the safety valve to prevent scaling deposit and
verify that the safety device is not blocked. If this is not done, damage may be caused and the
guarantee invalidated. For an installation with a booster pump; before starting up, after a long
period of disuse, turn the rotor following the advice in the manufacturer’s instructions.
2. MAINTENANCE BY A QUALIFIED PERSON
- Scaling: Remove the scale sludge. Do not scrape or hammer the lime scale deposited on the
casing, as this may damage the lining.
- Magnesium anode: change the magnesium anode every 2 years or when its diameter is lower
than 10 mm.
- Heating element: the replacement of a sheathed heating element involves draining of the water
heater and replacement of the flange gasket. Reassemble the heating element, reasonably tight
nuts (cross tightening), check that there is no leakage after the first heating-up, tighten again if
necessary
- Drain: Turn off power and cold water supply. Open hot water taps and drain valve of the safety
device.
Spare parts list: thermostat, flange gasket, heating element, heating light indicator, magnesium
anode, connection wires, electric switch. The guarantee requires genuine manufacturer’s parts
to be used.
Advice to the user
When the water has a TH > 20°f, it is recommended that this be treated. When a softener
is used, the water hardness must remain above 15°f.
In case of prolonged absence, especially in winter, drain your appliance following the
procedure.