6.5 BF Line Levelling Measurement*
Step Key/Screen Description
1.
Initialize the BIF method.
2.
Initiate measurement to Benchmark.
3.
Backsight measurement displayed.
4.
To start 'Intermediate sight' measurement,
go to menu set 'Intermediate Sight' to ON
or press Height & Distance key.
5.
Intermediate sight measurement
displayed.
6.
Go to menu set 'Intermediate Sight' to OFF
or press Height & Distance key, then
measure to the foresight staff.
7.
Foresight measurement displayed.
8.
System refreshes a standby display for
measurement to the backsight of next
change point.
Step Key/Screen Description
1.
Initialize the BF method
2.
Initiate measurement to Benchmark
3.
Backsight measurement displayed.
4.
Measure to the foresight staff.
5.
Foresight measurement displayed.
6.
System refreshes a standby display for
measurement to the backsight of next
change point.