Bosch AL 1830CV (1.600.A00.5B3) [15/203] Troubleshooting causes and corrective measures

Bosch AL 1830CV (1.600.A00.5B3) [15/203] Troubleshooting causes and corrective measures
English | 15
Bosch Power Tools 1 609 92A 1N1 | (22.2.16)
allowable charging temperature range is reached, the battery charger automatically
switches to rapid charging.
Flashing Red Battery Charge Indicator 2
A flashing red battery charge indicator 2 indicates a different mal-
function of the charging procedure, see section “Troubleshooting
Causes and Corrective Measures”.
Troubleshooting – Causes and Corrective Measures
Working Advice
With continuous or several repetitive charging cycles without interruption, the charg-
er can warm up. This is not meaningful and does not indicate a technical defect of the
battery charger.
A significantly reduced working period after charging indicates that the battery is
used and must be replaced.
Cause Corrective Measure
AL 1815 CV: Continuous lighting of the battery charge indicator 3
AL 1830 CV: Continuous lighting of the battery charge indicator 3
Flashing red battery charge indicator 2
AL 1815 CV / AL 1830 CV: No charging procedure possible
The battery is not attached (correctly) Attach battery to charger correctly
Battery contacts
contaminated
Clean the battery contacts (e.g. by
inserting and removing the battery
several times) or replace the battery
Battery pack defective Replace the battery
Battery charge indicators 3 or 2 do not light up
Mains plug of battery charger not plugged
in (properly)
Insert mains plug (fully) into the socket
outlet
Socket outlet, mains cable or battery
charger defective
Check the mains voltage; have the
battery charger checked by an authorised
after-sales service agent for Bosch power
tools
OBJ_BUCH-2418-004.book Page 15 Monday, February 22, 2016 10:47 AM

Содержание

Похожие устройства

Скачать