Trotec Speedy 300 flexx [7/54] Control system
![Trotec Speedy 300 fiber [7/54] Control system](/views2/1404702/page7/bg7.png)
8017 Trotec Speedy 300 fiber
GENERAL
28/07/2015 Trotec Produktions- und Vertriebs GmbH_Linzer Strasse 156, A-4600 Wels, Austria, Technical Support 7 / 54
tel_+43 (0)7242 239-7000, fax_+43 (0)7242 239-7380, mailto: techsupport@troteclaser.com
1.4 Technical Data / Device Specification
Mechanic
Working area
29 x 17 inch / 726 x 432 mm
Max. size of workpiece
29.5 x 17.3 inch / 750 x 440 mm
Max. height of workpiece
6.6 inch / 169 mm with 3.2 inch lens
4.8 inch / 123 mm with 5.0 inch lens
Max. engraving speed
78 inch/sec / 200 cm/sec for fiber
Motor
Brushless DC Servo motor
Encoder
Increment
Workpiece table
Solid metal (ferro-magnetic)
Max. load of workpiece
44 lbs / 20 kg
Lenses
3.2, 5.0 inch
Features
Standard:
Electro-optic autofocus, Laser pointer (655nm, < 0,99mWcw), Coaxial air assist (without pump),
Ferro-magnetic working table, 3.2 inch lens, USB connection, JobControl Expert software
Optional:
Honeycomb cutting table, Rotary attachment, Harsh environment protection kit, Laserpower upgrade,
Air assist including compressor, Temperature sensor, Vacuum table, Data import MAC, i-cut, Trolley
Table
Control system
Laserpower
Adjustable from 0 - 100%
Interface Hardware
RS-232-C: Data Rate 19.200 – 155.200 Baud
USB: Data Rate 460.800 Baud
Interface Software
JobControl, HPGL
Laser Equipment
Laser tube
Pulsed fiber laser, maintenance free
Laserpower: 10W, 20W, 30W, 50W
Wavelength
1064 nm
Cooling system
Air cooling unit
All systems air-cooled
Electricity, Power, Fuse
Voltage
Single phase 230V / 50Hz or 115V / 60 Hz
Power consumption
710 W for 50W unit
Recommended fuse
10A (115V / 230V)
Dimensions
Width/depth/height (incl. trolley)
42.9 x 35.1 x 41.8 inch / 1090 x 890 x 1060 mm
Weight (approx.)
297 lbs / 135 kg
Ambient conditions
Temperature
59°F to 77°F / +15°C to +25°C
Humidity
40% to max 70%, not condensing
Laser Safety
Laser class
CDRH Laser Safety
Laser Class 2
CE compliant, FDA approved
Interlock
Duplicate interlock safety system
SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
SEPTEMBER 2010
Содержание
- Operation manual 1
- Trotec speedy 300 fiber 1
- Table of contents 3
- Additional information 48 4
- Caution 5
- General 5
- Operation manual use general information 5
- Designated use 6
- Disposal remarks 6
- Ambient conditions 7
- Control system 7
- Cooling system 7
- Dimensions 7
- Electricity power fuse 7
- Features 7
- Laser equipment 7
- Laser safety 7
- Mechanic 7
- Technical data device specification 7
- It is recommended to enter data such as serial number and year of manufacture into the it is recommended to enter data such as serial number and year of manufacture into the manufacturer s label above so that you always have this data at hand when required 8
- Manufacturer s label 8
- The manufacturer s label is located on the back of the machine see picture below 8
- Eu declaration of conformity 9
- General safety information 10
- Please read this chapter before operating or servicing a trotec speedy 300 fiber laser system 10
- Safety 10
- Laser safety information 11
- Safety precautions when operating the machine 13
- The warning and information labels are attached in such positions of the machine that could represent a source of danger during set up and operation therefore follow the information on the labels if labels are lost or damaged they must be replaced immediately 14
- Warning and information labels 14
- Before operation 16
- Unpacking 16
- Contents of delivery 17
- Location 18
- Electrical requirements 19
- Computer requirements 20
- Exhaust system requirements 20
- Connecting the mains 21
- Connections 21
- Connecting the computer 22
- Connecting the exhaust system 23
- Machine view and connections 24
- Operation 24
- Power switch on off 28
- Keypad 29
- First steps 32
- Produce the first samples 35
- Rotary attachment 37
- Cleaning the system 41
- Maintenance 41
- Cleaning the lens 42
- Cleaning the optical parts 42
- Cleaning the mirrors 2 and 3 44
- Mirror 2 44
- Mirror 3 45
- Maintenance plan 47
- Additional information 48
- Caution when processing conductive materials carbon fibers conductive dust or particles in the ambient air might damage electrical components and lead to short circuits bear in mind that those defects are not warranted 48
- Material table 48
- Metals 48
- Nonmetals 48
- Speedy 300 fiber 48
- Tips for troubleshooting 49
- Acceptance report 50
- Training schedule 51
- If you face any trouble with the machine please provide the following information and add a servicefile procedure is described on the following pages 52
- Response form 52
- How to create a service file 53
Похожие устройства
- Trotec Speedy 300 flexx Технические характеристики
- Trotec Speedy 360 Инструкция по эксплуатации
- Trotec Speedy 360 Технические характеристики
- Trotec Speedy 360 fiber Инструкция по эксплуатации
- Trotec Speedy 360 fiber Технические характеристики
- Trotec Speedy 500 Инструкция по эксплуатации
- Trotec Speedy 500 Технические характеристики
- Trotec SP 500 Инструкция по эксплуатации
- Trotec SP 500 Технические характеристики
- Trotec SP 1500 Инструкция по эксплуатации
- Trotec SP 1500 Технические характеристики
- Trotec SP2000 Инструкция по эксплуатации
- Trotec SP2000 Технические характеристики
- Trotec SP3000 Инструкция по эксплуатации
- Trotec SP3000 Технические характеристики
- Trotec Multi-Color-Jet Инструкция по эксплуатации
- Trotec SpeedMarker 100 Инструкция по эксплуатации
- Trotec SpeedMarker 100 Технические характеристики
- Trotec SpeedMarker 300 Инструкция по эксплуатации
- Trotec SpeedMarker 300 Технические характеристики