Trotec SP2000​ [37/51] Sp 500

Trotec SP2000​ [37/51] Sp 500
SP 500
Version 2.0 © TROTEC Produktions- u. Vertriebs GmbH
37 / 51
Technical changes reserved Freilingerstraße 99, A-4614 Marchtrenk
www.troteclaser.com
Exhaust System
Trotec advises to use the Atmos Duo Plus for the SP 500.
If only a Cutting table is installed, a VENT 3000 would be sufficient
.
The laser may only be operated with properly installed and operating exhaust system.
Fumes and dust created during cutting or engraving have to be exhausted properly.
Some materials when cut or engraved can produce fumes that are hazardous in con-
centrated amounts.
Damage to the system caused by the use of no or improper extraction equipment will
not be covered by warranty.
The life time of optics and mechanical components will be reduced by fumes and dust
accumulating in the machine. This will be avoided by a capable exhaust system.
The cutting quality will be reduced by fumes and dust accumulating in the machine.
This will be avoided by a capable exhaust system.
The laser power interacting with the work-piece will be reduced by fumes and dust ac-
cumulating in the machine. This will be avoided by a capable exhaust system.
Depending on the type of table installed in the machine the exhaust requirements and recommended
Trotec exhaust systems for standard applications are:
Flow rate Pressure
Atmos
Mono
Atmos
Duo
Vent
3000
Vent
HP
Head Exhaust (45mm) 50 m³/h 5300 Pa
Vacuum table (75mm) 250 m³/h 3900 Pa
Cutting table (75mm) 350 m³/h 1500 Pa
Standard table Not applicable (Table Exhaust inactive)
Monitoring point for flow-rate and pressure is at the exhaust port at the laser machine. Pressure loss
by hoses / pipes or filter parts of the exhaust has to be determined and additionally calculated when
selecting a proper exhaust.
The exhaust power which is available for the application will be reduced by e.g. bend-
ing, small hose diameters and long hoses.
Therefore, avoid bending, keep hoses as short as possible and use hoses with diame-
ters as large as possible.
Applications generating large amounts of dust or fumes may require a stronger ex-
haust system.
Also the use of separate exhaust systems for head and table exhaust may be neces-
sary.
It is absolutely necessary to consult your distributor in such cases.