AEG BHG 750 W [15/52] Troubleshooting

AEG BHG 750 W [15/52] Troubleshooting
15
Installation - for contractors
Note
Carry out all electrical connection and installation
work in accordance with national and regional reg-
ulations.
Note
Ensure a standard socket or junction box for a per-
manent power supply is installed at a distance of at
least 10 cm from the side of the appliance.
11. Troubleshooting
The power cable must only be replaced by a qualied
contractor using original spare parts.
12. Appliance handover
» Explain the functions of the appliance to the user.
» Draw special attention to the safety instructions.
» Pass on the operating and installation instructions to
the user.
13. Specication
13.1 Dimensions
a10
a20
a30
i13
i13
D0000026162
BHG
750 W
BHG
1000 W
BHG
750 C
a10 Appliance Height mm 1453 1781 1658
a30 Appliance Depth mm 115 115 110
a20 Appliance Width mm 480 550 600
i13 Wall mounting
bracket
Vertical hole
spacing
mm 1230 1599 1435
Horizontal
hole spacing
mm 350 400 450
13.2 Minimum clearances
≥200
≥150
≥150
D0000026163
13.3 Data table
BHG 750 W BHG 750 C BHG 1000 W
231950 231951 233861
Electrical data
Power connection 1/N ~ 230/240
V
1/N ~ 230/240
V
1/N ~ 230/240
V
Connected load kW 0.75 0.75 1.0
Dimensions
Height mm 1453 1658 1781
Width mm 480 600 550
Depth mm 115 110 115
Weights
Weight kg 16 24 30
Versions
Frost protection
setting
°C 5 5 5
IP rating IP24 IP24 IP24
Safety category II II II
Colour Traffic white,
RAL 9016
Chrome Traffic white,
RAL 9016
Values
Setting range °C 5-30 5-30 5-30