Fluke 710 Руководство по калибровке онлайн [7/20] 365595
![Fluke 710 Руководство по калибровке онлайн [7/20] 365595](/views2/1435991/page7/bg7.png)
Precision Loop Calibrator
Specifications
3
Safety .......................................................... IEC 61010-1: Pollution Degree 2
Electromagnetic Compatibility (EMC)
International ......................................... IEC 61326-1: Portable Electromagnetic
Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally
generated and/or uses conductively-coupled
radio frequency energy that is necessary for
the internal function of the equipment itself.
Class A: Equipment is suitable for use in all
establishments other than domestic and those
directly connected to a low-voltage power
supply network that supplies buildings used for
domestic purposes. There may be potential
difficulties in ensuring electromagnetic
compatibility in other environments due to
conducted and radiated disturbances.
Caution: This equipment is not intended for
use in residential environments and may not
provide adequate protection to radio reception
in such environments.
Emissions that exceed the levels required by
CISPR 11 can occur when the equipment is
connected to a test object.
Korea (KCC) ......................................... Class A Equipment (Industrial Broadcasting &
Communication Equipment)
Class A: Equipment meets requirements for
industrial electromagnetic wave equipment
and the seller or user should take notice of it.
This equipment is intended for use in business
environments and not to be used in homes.
USA (FCC) ........................................... 47 CFR 15 subpart B. This product is
considered an exempt device per clause
15.103.
Содержание
- 709h 710 1
- 709h 710 calibration manual 1
- Warranty 2
- Table of contents 3
- Contact fluke 5
- Introduction 5
- To prevent possible electrical shock fire or personal injury read all safety information before you use the product 5
- Xw warning 5
- Safety information 6
- Specifications 6
- Battery replacement 8
- Clean the product 8
- Maintenance 8
- Xw warning 8
- Precision loop calibrator 9
- 709h 710 10
- Performance verification tests 10
- Required test equipment 10
- Table 1 is a list of the required equipment for the performance verification tests and calibration adjustment 10
- The performance tests verify the complete operation of the product and measure the accuracy of each function against product specifications if the product fails a part of the test calibration adjustment or repair is necessary see calibration adjustment procedure 10
- The performance verification tests check the accuracy of each product function against its specifications if the product fails any of these tests calibration adjustment or repair is necessary 10
- To prevent possible electrical shock fire or personal injury do not perform the performance test or verification test procedures unless the product is fully assembled 10
- Xw warning 10
- Dc current source mode 11
- 709h 710 12
- A connect a test lead from the red aux terminal of the dc calibrator calibrator to the dmm i input 12
- B connect a test lead from the black aux terminal of the calibrator to the com terminal on the product 12
- C connect a test lead from the dmm lo input to the product terminal see figure 3 12
- Connect the product 12
- Dc current measurement mode 12
- Disconnect all connections to the product 12
- Make sure that the product shows source in the upper left corner 12
- Push the rotary knob 12
- See table 2 to verify the readings on the dmm for the subsequent tests no adjustment is necessary for test 1 12
- Set the dmm to measure dc current 12
- Test 2 push twice to select 12 00 ma verify the readings 12
- Test 3 push twice to select 20 00 ma push and rotate the knob until 24 00 ma is shown verify the readings 12
- The product shows measure 12
- To verify the performance of the dc current measurement function 12
- Turn the rotary knob to select ma measure 12
- Dc voltage measurement mode 14
- Hart transmitter 709h 710 only 15
- Calibration adjustment procedure 16
- Ma measure mode 16
- Ma source 17
- Voltage measure 18
- Precision loop calibrator 19
- User replaceable parts 19
- User replaceable parts are listed in table 3 and shown in figure 6 for more information about these items and their prices contact a fluke representative see the contact fluke section 19
- 709h 710 20
- Calibration manual 20
- Figure 6 user replaceable parts 20
Похожие устройства
- Fluke 710 Краткий справочник
- Fluke 710 Руководство по эксплуатации
- Fluke 789 Положение об энергозависимости памяти
- Fluke 789 Приложение к руководству по калибровке
- Fluke 789 Приложение к Руководству по эксплуатации
- Fluke 789 ProcessMeter
- Fluke 789 Паспорт безопасности
- Fluke 789 Краткий справочник
- Fluke 789 Руководство по калибровке
- Fluke 789 Руководство по эксплуатации
- Fluke 787B Положение об энергозависимости памяти
- Fluke 787B Приложение к руководству по калибровке
- Fluke 787B ProcessMeter
- Fluke 787B Приложение к Руководству по эксплуатации
- Fluke 787B Краткий справочник
- Fluke 787B Паспорт безопасности
- Fluke 787B Руководство по эксплуатации
- Fluke 787B Руководство по калибровке
- Fluke 787 Положение об энергозависимости памяти
- Fluke 787 Приложение к руководству по калибровке