D-Link DGS-3700-12 [7/338] Accessing the switch via the serial port

D-Link DGS-3420-28SC [7/338] Accessing the switch via the serial port
DGS-3312SR Layer 3 Gigabit Switch
1
1
INTRODUCTION
The switch can be managed through the switch’s serial port, Telnet, or the Web-based management agent. The Command Line
Interface (CLI) can be used to configure and manage the switch via the serial port or Telnet interfaces.
This manual provides a reference for all of the commands contained in the CLI. Configuration and management of the switch
via the Web-based management agent is discussed in the User’s Guide.
Accessing the Switch via the Serial Port
The switch’s serial port’s default settings are as follows:
9600 baud
no parity
8 data bits
1 stop bit
A computer running a terminal emulation program capable of emulating a VT-100 terminal and a serial port configured as
above is then connected to the switch’s serial port via an RS-232 DB-9 cable.
With the serial port properly connected to a management computer, the following screen should be visible. If this screen does
not appear, try pressing Ctrl+r to refresh the console screen.
Figure 1-1. Initial CLI screen