9. TROUBLESHOOTING
In case of emergency, please, use the troubleshooting methods shown in
tables. If it is impossible to solve problems with these methods, apply to
the service center.
Problem Possible cause Remedy
Poor atomizing (insufficient
capacity)
The unit is operating in the minimized
mode (low atomizing frequency)
There is no problem. If you need to switch
to the intensive mode of operation, turn the
regulator handle all the way to the right.
The atomizer is clogged Clean the atomizer.
Temperature of water in the tank is too low
Set maximum capacity. The humidifier’s
capacity will go up after a while.
No atomizing
The power cord is poorly connected
to the outlet
Connect the power cord into the outlet
carefully
There is white deposit on objects
around the humidifier (salts,
separating out from water)
1. Lime deposits have formed on the
membrane
2. There is a lot of salts in the water used
(calcium and magnesium)
1. Clean the humidifier’s membrane with a
special brush
2. Use filtered water
Steam has an unpleasant odor
Stale water is used
Clean the unit according to the cleaning
and servicing instructions and fill the tank
with fresh water
Remains of stale water or waste have
accumulated in the unit’s case or the
atomizer
IMPORTANT!
To avoid deformation or wear of working surfaces,
resulting in decreased atomizing or other malfunctions, do
not use metallic brushes, blades or talc powder to wipe
the atomizer’s surface. The water tank may leak upon
heavy impacts. In case of water leakage, immediately
stop using the unit and contact a service center. To keep
the unit dry, remove water after cleaning and make sure
to dry the unit’s case. Make sure that there is no water left
inside the unit’s case. Prior to a long break in using the
unit, dry its surface and pack it into a plastic bag, then
put it into a box. Store the unit in a low-humidity room.
Storing the unit undried results in generation of mold
Problem Possible cause Remedy
Condensate is formed on the
upper part of the humidifier and
on surrounding objects, when it is
operating.
1. High humidification intensity is set.
2. High room humidity and temperature.
Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
Water appears next to the humidifier,
when it is operating.
1. High humidification intensity is set.
2. Lime deposits have formed on the
membrane and in grooves for water (in
the unit’s base).
1. Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
2. Clean the unit according to the cleaning
and servicing instructions.
Water appears next to the humidifier,
when it is not operating
Water tank is leaking
You need to contact an authorized service
center