Faber INCA LUX GLASS EG8 X/BK A52 Инструкция по эксплуатации онлайн [13/140] 375576

Faber INCA LUX GLASS EG8 X/BK A52 Инструкция по эксплуатации онлайн [13/140] 375576
EN
1
3
13
Activated Charcoal Filter (Recirculation Version)
This cannot be washed or regenerated, and must be changed when led S1 starts to flash, or at
least once every 4 months. The Alarm signal, if it has been activated, only appears when the
Suction motor is turned on.
Activating the alarm signal
In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on
installation or at a later date.
Turn the Lights and the Suction Motor off.
Press button T2 and hold it for 5 seconds until the LED flashes twice in confirmation:
CHANGING
Resetting the alarm signal
Turn the Lights and the Suction Motor off.
Press T3 and hold for at least 3 seconds, until LED flashes
three times in confirmation.
Changing the Filter
Open the doors.
Remove the Metal Grease Filter.
Remove the saturated Activated Charcoal Filters, as indicated
(A).
Fit the new Filters, as indicated (B).
Replace the Metal grease filters.
Close the doors.
A
B
Lighting unit
For replacement contact technical support ("To purchase
contact technical support").

Содержание

Похожие устройства

Activated Charcoa Filter Recirculation Version This cannot be washed or regenerated and must be changed when led SI starts to flash or at least once every 4 months The Alarm signal if it has been activated only appears when the Suction motor is turned on Activating the alarm signa In Recirculation Version Hoods the Filter Saturation Alarm must installation or at a later date Turn the Lights and the Suction Motor off Press button T2 and hold it for 5 seconds until the LED flashes twice in confirmation be activated on CHANGING Resetting the alarm signal Turn the Lights and the Suction Motor off Press T3 and hold for at least 3 seconds until LED flashes three times in confirmation Changing the Filter Open the doors Remove the Metal Grease Filter Remove the saturated Activated Charcoal Filters as indicated A Fit the new Filters as indicated B Replace the Metal grease filters Close the doors Lighting unit For replacement contact technical support To purchase contact technical support EN 13

Скачать