D-Link DGS-1210-28X/ME [270/519] Config erps instance timer

D-Link DGS-1210-12TS/ME [270/519] Config erps instance timer
DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
252
Description
The config erps instance protected_vlan commanmd is used to
configure the VLANs that are protected by the ERPS function.
The instance R-
APS VLAN cannot be the protected VLAN. The
protected VLAN can be one that has already been created, or it can
be used for a VLAN that has not yet been created.
Parameters
protected_vlan [add | delete] Specif
ies to add VLANs to the
protected VLAN group, or delete VLANs from the protected VLAN
group.
Restrictions Only Administrator, operator and power user-level users can issue
this command.
Example usage:
To configure the protected VLAN for a specific instance:
DGS-1210-28MP/ME:5# config erps instance 1 protected_vlan add vlanid 10-20
Command: config erps instance 1 protected_vlan add vlanid 10-20
Success.
DGS-1210-28MP/ME:5#
config erps instance timer
Purpose Used to configure the ERPS timers for a spe
cific physical ring’s
instance.
Syntax
config erps instance <value 1-16> timer [[ holdoff_time <integer
0-10000>] | [ guard_time <integer 10-2000>] | [ wtr_time <integer
1-12>]]
Description
The config erps instance timer commanmd is used to configure
the protocol timers.
Holdoff Timer
The Holdoff Timer is used to filter out
intermittent link faults when link failures occur during the
protection switching process. When a ring node detects a link
failure, it will start the holdoff timer and report the link failure
event (R-
APS BPDU with SF flag) after the link failure is
confirmed within the specified time period.
Guard Timer Guard Timer is used to prevent ring nodes from
receiving outdated R-APS messages. This timer is used during
the protection switchi
ng process after recovering from a link
failure. When the link node detects a link recovery, it will report
the link failure recovery event (R-APS PDU with NR flag) and
start the guard timer. Before the guard timer expires, all
received R-APS messages will
be ignored by this ring node,
except in the case where there is a burst of three R-APS event
messages. This indicates that the sub-
ring topology has
changed, meaning that the node needs to flush the FDB that
has been received on the node. In this case, the recovered link
will not go into a blocking state. The Guard Timer should be
greater than the maximum expected forwarding delay for which
one R-APS message circles around the ring.
WTR Timer The WTR Timer is used to prevent the frequent
operation of the protection switch due to an intermittent defect.
This timer is used during the protection switching process

Содержание