Zkteco TS5000A Инструкция по эксплуатации(ENG) онлайн [8/10] 409372

Zkteco TS5000A Инструкция по эксплуатации(ENG) онлайн [8/10] 409372
Menu Operation 7
5. Open duration
Press the "UP" and "DOWN" button to adjust the time. Press "OK" button to save.
After the barrier is open, it will automatically close if no one passes. The default setting time is 5
seconds.
6. Turning angle
Press the UP and DOWN button to set turning angle. Press OK button to save. The turning angle can
be adjusted from 1 to 30 degree. The default turning angle is 10 degree.
7. Push angle
Press the UP and DOWN button to set push angle. Press OK button to save. The push angel can be
adjusted from 1 to 30 degree. The default push angle is 5 degree.
8. Clutch mode
Normal open
Normal Close
9. Max motor running time
Press the "UP" and "DOWN" button to adjust the time. Press "OK" button to save.
It is designed to prevent the motor idling when the control panel is break down for external detection and
other reasons causing no signal. The default setting for the maximum motor running time is 3 seconds.
10. Device number
Press the "UP" and "DOWN" button to adjust the time. Press "OK" button to save.
When many machines are put together, different device number can be used to distinguish, the default
number is 1.
11. Device information
The basic information of the display panel includes type, version and etc.
12. System initialization
After success of the initialization, the panel parameters will be restored to the factory setting and
the counter will be test.
13. Test mode
The turnstile will open Bi-direction repeatedly. It is mainly used to test the stability and aging of
control board.
Скачать