Dometic TEC 40D [17/220] Attaching the exhaust pipe

Dometic TEC 40D [17/220] Attaching the exhaust pipe
EN
TEC40D Installation
17
Mount the gaskets (available as accessory) to the casing and fix them with the
srews (fig. 3, page 4).
Position the casing in the desired area and attach it with the appropriate screws
(fig. 4, page 4).
Insert the engine plate into the casing and screw it into place (fig. 5, page 4).
Mount the casing cover and attach it with the pins (fig. 6, page 4).
9.3 Attaching the exhaust pipe
Observe the following instructions when installing the exhaust pipe:
Do not create any sharp bends which will inhibit the flow of exhaust fumes.
Connect the hose (fig. 7 2, page 5) to the muffler (fig. 7 1, page 5) and attach
it with the clamps (fig. 7 4, page 5)
Secure the exhaust pipe extension to the vehicle floor (fig. 7 3, page 5).
9.4 Installing the tank and fuel supply line
Please observe the following instructions for the installation location:
The tank bottom must be positioned at a maximum of 1 m below the bottom of
the generator.
The top of the tank must not be higher than the top of the generator.
The maximum horizontal distance between generator and fuel tank is 3 m.
Lay the fuel hoses as straight as possible (fig. 8, page 5).
Secure the tank, see fig. 8, page 5 and chapter “Connecting the float” on
page 21.
Connect the fuel hose (fig. 9 1, page 6) to the fuel filter (fig. 9 2, page 6).
Connect the hose to the fuel return (fig. 9 3, page 6).
Secure the hoses with clamps.