Dometic CoolAir RT-IK для Renault T+C, H1 [21/280] Starting and ending configuration mode

Dometic CoolAir RT-IK для Renault T+C, H1 [21/280] Starting and ending configuration mode
21
EN
CoolAir RT780 Configuration of unit software
8.1 Starting and ending configuration mode
The adjustable parameters can be changed in configuration mode:
When using the button to switch on the unit, hold both buttons +
and
pressed until the compressor LED flashes.
You are now in configuration mode.
The display version (e. g. “3.1S”) appears in the display for 2 seconds.
The first digit of the display shows the menu level and the second and third
digits show the parameters which can be set, e.g.
1.17 for menu level 1 and a
set target value of 17 °C.
I
Press the button to quit configuration mode.
8.2 Menu level 1: Set temperature
The unit always starts with a defined value for the room temperature. This
parameter can be configured between 17 and 30 °C (62 and 86 °F).
Start configuration mode (chapter “Starting and ending configuration mode”
on page 21).
The first digit of the display shows the menu level and the second and third
show the parameter which can be set.
Press the button to change the parameters.
Use the +
and
buttons
to select the target value (in °C) at which the unit
should start operation.
The digits in the display flash until the parameter you entered is confirmed.
Press the button to confirm your entry.
The set value is saved and is then used when the unit is restarted.
You are now in menu level 1 again and can use the +
and
buttons to switch
between menu levels.
NOTE
If you make no entry on the control panel for 60 seconds, the unit quits
configuration mode and shuts down.
RT780-Renault-H1--I-16s.book Seite 21 Mittwoch, 6. September 2017 5:31 17

Содержание

Похожие устройства

Скачать