Fluke 355 [22/26] User replaceable parts
![Fluke FLK-353 [22/26] User replaceable parts](/views2/1005189/page22/bg16.png)
353/355
Users Manual
14
Maintenance
XW Warning
To avoid electrical shock, or personal injury:
• Repairs or servicing not covered in this
manual should be performed only by
qualified personnel.
• Disconnect test leads from the Meter
before removing its back cover.
• Never use the Meter with the back cover
removed.
WCaution
• To avoid contamination or static damage
of the Meter, do not touch the circuit
board without proper static protection.
• If the Meter is not going to be used for an
extended time, remove the battery. Do
not store the Meter in high temperature
or high-humidity environments.
Cleaning the Meter
WCaution
To avoid damaging the meter, do not use
abrasives or solvents on this instrument.
Periodically clean the Meter by wiping it with a damp
cloth.
Changing the Batteries
When battery voltage drops below the value required for
proper operation, the battery symbol (B) appears and
the Meter beeps.
To change the batteries:
1. Turn the Meter off and disconnect the test leads.
2. Using a screwdriver, open the battery cover on the
back of the Meter.
3. Replace the batteries with six new AA/LR6 batteries.
Observe correct polarity when installing the batteries.
4. Close the back cover and tighten the screw.
User Replaceable Parts
Refer to Contacting Fluke for more information.
• C43 Soft carrying case
• TL224 1.5 m silicone rubber test leads
• TP2 Test Probes
• AC285 Alligator Clips
Содержание
- 355 users manual 1
- Clamp meter 1
- Warranty 2
- Table of contents 3
- Title page 3
- List of tables 5
- Table title page 5
- Figure title page 7
- List of figures 7
- Clamp meter 9
- Contacting fluke 9
- Introduction 9
- Safety information 10
- Xw warnings read first 10
- Features 13
- Display 15
- Maxminavglive 15
- Measuring ac or dc current 16
- Using the meter 16
- Xw warning 16
- Measuring inrush current 17
- Measuring ac and dc voltage 355 only 18
- Clamp meter using the meter 19
- Fbq06 eps 19
- Figure 6 dc voltage measurement 19
- Testing continuity 355 only 20
- Xw warning 20
- Measuring resistance 355 only 21
- Xw warning 21
- Changing the batteries 22
- Cleaning the meter 22
- Maintenance 22
- User replaceable parts 22
- Xw warning 22
- Current measurement 10 hz to 100hz 23
- Current measurement 100 hz to 1 khz 23
- Electrical specifications 23
- Specifications 23
- Ohms measurement 355 only 24
- Voltage measurement 355 only 10 hz to 100 hz 24
- Voltage measurement 355 only 100 hz to 1 khz 24
- Continuity beeper 355 25
- Frequency measurement 25
- General specifications 25
- Environmental specifications 26
- Standards and agency approval specifications 26
Похожие устройства
- Boif AL120 В00100 Инструкция по эксплуатации
- Supra SWD-605 Инструкция по эксплуатации
- LG MS-2342A Инструкция по эксплуатации
- Fluke 373 Инструкция по эксплуатации
- Bosch WLX 24463 OE Инструкция по эксплуатации
- DBX 1215 Инструкция по эксплуатации
- Geo-Fennel Ecoline EL601 D1200 Инструкция по эксплуатации
- Supra SDM-3150 Инструкция по эксплуатации
- Belkin F7D1301ru Инструкция по эксплуатации
- Fluke 374 Инструкция по эксплуатации
- Bosch WLX 20463 OE Инструкция по эксплуатации
- DBX 1231 Инструкция по эксплуатации
- LG MS-2324B Инструкция по эксплуатации
- Ada 6D Servoliner А00139 Инструкция по эксплуатации
- Supra SDM-3110 Инструкция по эксплуатации
- Fluke 375 Инструкция по эксплуатации
- LG MS-2052F Series Инструкция по эксплуатации
- Belkin F7D1401ru Инструкция по эксплуатации
- DBX iEQ-15 Инструкция по эксплуатации
- Bosch WLX 20163 OE Инструкция по эксплуатации