Fluke 355 [26/26] Standards and agency approval specifications
![Fluke 355 [26/26] Standards and agency approval specifications](/views2/1005189/page26/bg1a.png)
353/355
Users Manual
18
Standards and Agency Approval Specifications
Design
Standards and
Compliance
EN61010-032 CAT IV 600 V,
IEC/EN 61326-1:1997
Agency
Approvals
P, ), ;, ~
N10140
Over-voltage
Category
IEC61010-1 CAT III 1000 V,
CAT IV 600 V
Environmental Specifications
Operating
Temperature
32 °F to + 122 °F
(0 °C to +50 °C)
Storage
Temperature
-4 °F to 140 °F
(-20 °C to +60 °C)
Operating
Humidity
0 to 95 % (non-condensing)
Operating
Altitude
2000 m
Storage
Altitude
10,000 m
IP Rating
42 (indoor use only)
Drop Test
Requirements
1 m
EMI, RFI, EMC
FCC part 15, IEC/EN 61326-1:1997
class B, IEC/EN 61326:1997 3V/m,
performance criteria B, EN61325
Temperature
Coefficients
Current: 0.1 % of reading per °C
outside 22-24 °C
Voltage: 0.1 % of reading per °C
outside 22-24 °C
Содержание
- 355 users manual 1
- Clamp meter 1
- Warranty 2
- Table of contents 3
- Title page 3
- List of tables 5
- Table title page 5
- Figure title page 7
- List of figures 7
- Clamp meter 9
- Contacting fluke 9
- Introduction 9
- Safety information 10
- Xw warnings read first 10
- Features 13
- Display 15
- Maxminavglive 15
- Measuring ac or dc current 16
- Using the meter 16
- Xw warning 16
- Measuring inrush current 17
- Measuring ac and dc voltage 355 only 18
- Clamp meter using the meter 19
- Fbq06 eps 19
- Figure 6 dc voltage measurement 19
- Testing continuity 355 only 20
- Xw warning 20
- Measuring resistance 355 only 21
- Xw warning 21
- Changing the batteries 22
- Cleaning the meter 22
- Maintenance 22
- User replaceable parts 22
- Xw warning 22
- Current measurement 10 hz to 100hz 23
- Current measurement 100 hz to 1 khz 23
- Electrical specifications 23
- Specifications 23
- Ohms measurement 355 only 24
- Voltage measurement 355 only 10 hz to 100 hz 24
- Voltage measurement 355 only 100 hz to 1 khz 24
- Continuity beeper 355 25
- Frequency measurement 25
- General specifications 25
- Environmental specifications 26
- Standards and agency approval specifications 26
Похожие устройства
- Boif AL120 В00100 Инструкция по эксплуатации
- Supra SWD-605 Инструкция по эксплуатации
- LG MS-2342A Инструкция по эксплуатации
- Fluke 373 Инструкция по эксплуатации
- Bosch WLX 24463 OE Инструкция по эксплуатации
- DBX 1215 Инструкция по эксплуатации
- Geo-Fennel Ecoline EL601 D1200 Инструкция по эксплуатации
- Supra SDM-3150 Инструкция по эксплуатации
- Belkin F7D1301ru Инструкция по эксплуатации
- Fluke 374 Инструкция по эксплуатации
- Bosch WLX 20463 OE Инструкция по эксплуатации
- DBX 1231 Инструкция по эксплуатации
- LG MS-2324B Инструкция по эксплуатации
- Ada 6D Servoliner А00139 Инструкция по эксплуатации
- Supra SDM-3110 Инструкция по эксплуатации
- Fluke 375 Инструкция по эксплуатации
- LG MS-2052F Series Инструкция по эксплуатации
- Belkin F7D1401ru Инструкция по эксплуатации
- DBX iEQ-15 Инструкция по эксплуатации
- Bosch WLX 20163 OE Инструкция по эксплуатации