Using the inverter SinePower
18
10.2 Status indications
The blue LED (fig. 2 2) shows the operating condition of the inverter.
The inverter switches off if:
The battery voltage drops below 10 V (12 Vg connection) or
20 V (24 Vg connection).
The battery voltage exceeds 16.5 V (12 Vg connection) or
33 V (24 Vg connection).
The inverter is overloaded.
The inverter overheats.
If this happens, shut down the inverter with the main switch (fig. 2 1).
Check that the inverter is sufficiently ventilated and that the ventilation grilles are
unimpeded.
Wait 5 – 10 minutes and switch the inverter on again without any electric
consumers.
10.3 Switching to energy-saving mode
I
Display Input voltage
Constantly lit Normal mode
Long flash, short interruption Inverter overheated/Overload
Quick flash Overvoltage/Undervoltage
Off Other fault
NOTE
The energy-saving mode can be set with a remote control only.