Epson Stylus Pro XL [40/573] Esc set relative horizontal print position

Epson Stylus 1500 [40/573] Esc set relative horizontal print position
Individual Command Explanations C-33
ESC \ Set relative horizontal print position
ESC/P 2 ESC/P
Format
ASCII ESC \ nL nH
Hex 1B 5C nL nH
Decimal 27 92 nL nH
Parameter range
0 nH 127
0 nL 255
Function
Moves the horizontal print position left or right from the current position, as specified by
the following formula:
(horizontal position) =((nH × 256) + nL) × (defined unit) + (current position)
For positive (right) movement:
nH =
( )
INT
horizontal position current position
definedunit
( ) ( )
( )
×
1
256
nL =
( )
MOD
horizontal position current position
definedunit
( ) ( )
( )
×
1
256
For negative (left) movement:
nH =
( )
32768
1
256
×
INT
current position horizontal position
definedunit
( ) ( )
( )
nL =
( )
32768
1
256
×
MOD
current position horizontal position
definedunit
( ) ( )
( )
Notes
Set the defined unit with the ESC ( U command.
The default defined unit for this command is 1/120 inch in draft mode, and 1/180 inch
in LQ mode.
The printer ignores this command if it would move the print position outside the
printing area.