1.4 Electric panel
The electric panelisbuiltand wired in accordance with standardEN602041.Theelectric panelisaccessedfromthe
frontofthemachine.Beforeitcanbeaccessed,theunitmustbedisconnectedfromthepowersupplyusingthemain
switch, which functions as a doorlock. All the remote con
trols are implemented with low voltage signals at 24 V,
poweredbyanisolationtransformerpositioned insidethecontrolboard.Allthecontrolboardshavean aircirculation
systemwithauxiliaryfans.Thepositionofthemainswitchmakeswiringoperationsintheworksiteeasier.Thisavoids
severaldifficultoperatio
nsaswellashavingtotwistthepowercords.Alltheutilitiesareprotectedagainstsurgesand
short circuits. The circuit breaker setup can be configured for any load (optional). Thermal protection, however, is
carried out by thermistor chains. These are set in the windings of each electric motor and are controlled by onbo
ard
electronics.All machines are standardequipped with a phase sequence relay which inhibits compressor operation if
thephasesequenceisnotcarriedout:onlyonedirectionofrotationispossibleforscrollcompressors,aswellasforthe
screw and Rotary compressors.The unit is rated IP43 which makes it suitable fo
r outdoor installation. The control
board with the open panel maintains an IP20 rating. Inside the electrical control board of the Basic control there are
twomanualselectorstoenableremoteswitchingonoff,seasonalchangeover(onlyheatpumps)andtoselectlocalor
remoteco
ntrol:remoteconsentsareimplementedbyverylowvoltagecontactsplacedontheterminalboard.
1.4.1 Control microprocessor
LEWseriesunitshavetwodifferentmicroprocessorcontrollevels:
BasicCarelµChiller
AdvancedCarelseriespCO
Thelatter,inadditiontothefunctionsdescribedbelow,cancustomisethesoftwaretomeetallsystemrequests.These
includecas
cademanagementoftheunitswithstepcontrolorcascadelogic.Themicroprocessoronboardtheunit
controlsthevariousoperatingparameterswithanelectricpanelkeypad;
Compressorconnection/disconnectiontomaintainthesetpointofthechillerinletwaterT;
Alarmmanagement:Hi
gh/lowpressure;Antifreeze/Flowswitch;Pumpalarm
Alarmsignals
Displayofoperatingparameters
Evaporatorantifreezeprotection
Controlofmaximumnumberofcompressorstarts
RS232,RS485serialoutputcontrol(optional)
Incorrectphasesequence(notviewedondisplay,preventsthecompressorfromstarting)
Asforremotecommuni
cation,thecontrolscanbeconnectedtoadvancedBMSsystems.TheHSD(HiRefSoftware
Department)structureiscapableofassistingcustomersinintegrationoperations.Systeminterconnectivitycapabilities
aresummarisedbelow:
Availableserialports
RS232
RS485
Ethernet(“HiWeb”board)
GSMModem:withprepaidcardandrelativ
eantennaonboardthemachineforautonomoustwowaycontrolof
alarmsand/orsetpointvariations
Protocols
Carel [BuiltIn]
Modbus®[BuiltInwithAdvancedcontrols]
Modbus®[WithexternalgatewaywithBasiccontrols]
LonWorks®[Dedicatedserialboardtoberequestedwhenorderingthemachine]
BACn
et™[Withexternalgateway]
TCPIP [Withexternalgateway]
TREND®[Dedicatedserialboardtoberequestedwhenorderingthemachine]
(ref.Microprocessorcontrolmanualforfurtherdetails)