LCP 52 - 314 kW
Rated technical data of models for 4-pipe systems
(1) Water temperature 12/7 °C, outdoor air temperature 35 °C (UNI EN 14511:2011)
(2) Chilled water temperature 12/7 °C, recovery water temperature 40/45 °C
(3) Water temperature 40/45 °C, outdoor air temperature 7 °C D.B. - 6 °C W.B. (UNI EN 14511:2011)
(4) Sound power level measured according to UNI EN ISO 9614
LCP PL 144 164 194 214 244 274 294 324
Cooling mode (1) (E)
Cooling Capacity kW 138 153 187 214 232 258 291 303
Total power input kW 51,2 59,2 67,3 76,1 85,0 92,5 104 119
EER - 2,69 2,59 2,78 2,82 2,73 2,79 2,79 2,55
ESEER - 3,98 3,98 3,98 4,12 4,02 3,98 3,96 3,92
Eurovent Eciency Class - D D C C C C C D
User Water Pressure Drops l/h 23786 26453 32255 36969 39985 44458 50140 52308
User side water pump available pressure head kPa 48 42 44 57 55 38 46 60
Operation of the cooling and heating in total heat recovery (2)
Cooling Capacity kW 144 164 197 221 245 268 303 325
Heating Capacity kW 188 213 254 288 318 347 393 426
Total power input kW 45,6 51,3 60,2 70,4 77,0 83,6 94,6 106
Total COP - 7,27 7,36 7,49 7,24 7,31 7,36 7,37 7,08
Cooling side Water Pressure Drops l/h 24877 28350 33958 38164 42199 46159 52292 56090
Cooling side water pump available pressure head kPa 52 48 48 60 61 40 49 67
Heating side Water Pressure Drops l/h 32371 36806 43914 49724 54844 60025 67893 73463
Heatin side water pump available pressure head kPa 86 79 78 98 98 79 98 113
Heating mode (3) (E)
Heating Capacity kW 156 179 211 247 268 295 333 343
Total power input kW 48,0 54,0 62,5 72,1 77,8 86,4 96,9 108
COP - 3,26 3,3 3,38 3,42 3,45 3,41 3,43 3,17
Eurovent Eciency Class - A A A A A A A B
User Water Flow Rate l/h 27027 30857 36549 42640 46342 50963 57519 59230
User Water Pressure Drops kPa 62 57 56 75 72 59 73 76
General Data
Maximum absorbed current A 105 126 148 167 190 215 229 242
Startup current A 222 241 307 318 382 398 464 472
Startup current with softstarter A 145 157 200 207 248 259 301 307
n° of scroll compressor/ circuits - 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2
Buer tank dm
3
600 600 600 600 600 765 765 765
Sound power level (4) (E) dB(A) 79 80 81 82 82 83 83 83
Weight with pump and tank kg 1570 1710 1730 1920 1940 2290 2320 2350