Yaskawa CIMR-UU2A0192A [462/644] B d reference settings

Yaskawa CIMR-UU4A0124A [462/644] B d reference settings
No.
(Addr.
Hex)
Name LCD Display Description Values Page
d1-09
(0288)
Frequency Reference 9 Reference 9
All Modes
Sets the frequency reference for the drive. Setting units are
determined by parameter o1-03.
Note: The value set to o1-03 is changed to 1 and the
unit is changed to percentage automatically
when A1-02 is set to 6 or 7.
Default: 0.00 Hz
Min.: 0.00
Max.: 400.00
<1>
<2>
205
d1-10
(028B)
Frequency Reference 10 Reference 10
All Modes
Sets the frequency reference for the drive. Setting units are
determined by parameter o1-03.
Note: The value set to o1-03 is changed to 1 and the
unit is changed to percentage automatically
when A1-02 is set to 6 or 7.
Default: 0.00 Hz
Min.: 0.00
Max.: 400.00
<1>
<2>
205
d1-11
(028C)
Frequency Reference 11 Reference 11
All Modes
Sets the frequency reference for the drive. Setting units are
determined by parameter o1-03.
Note: The value set to o1-03 is changed to 1 and the
unit is changed to percentage automatically
when A1-02 is set to 6 or 7.
Default: 0.00 Hz
Min.: 0.00
Max.: 400.00
<1>
<2>
205
d1-12
(028D)
Frequency Reference 12 Reference 12
All Modes
Sets the frequency reference for the drive. Setting units are
determined by parameter o1-03.
Note: The value set to o1-03 is changed to 1 and the
unit is changed to percentage automatically
when A1-02 is set to 6 or 7.
Default: 0.00 Hz
Min.: 0.00
Max.: 400.00
<1>
<2>
205
d1-13
(028E)
Frequency Reference 13 Reference 13
All Modes
Sets the frequency reference for the drive. Setting units are
determined by parameter o1-03.
Note: The value set to o1-03 is changed to 1 and the
unit is changed to percentage automatically
when A1-02 is set to 6 or 7.
Default: 0.00 Hz
Min.: 0.00
Max.: 400.00
<1>
<2>
205
d1-14
(028F)
Frequency Reference 14 Reference 14
All Modes
Sets the frequency reference for the drive. Setting units are
determined by parameter o1-03.
Note: The value set to o1-03 is changed to 1 and the
unit is changed to percentage automatically
when A1-02 is set to 6 or 7.
Default: 0.00 Hz
Min.: 0.00
Max.: 400.00
<1>
<2>
205
d1-15
(0290)
Frequency Reference 15 Reference 15
All Modes
Sets the frequency reference for the drive. Setting units are
determined by parameter o1-03.
Note: The value set to o1-03 is changed to 1 and the
unit is changed to percentage automatically
when A1-02 is set to 6 or 7.
Default: 0.00 Hz
Min.: 0.00
Max.: 400.00
<1>
<2>
205
d1-16
(0291)
Frequency Reference 16 Reference 16
All Modes
Sets the frequency reference for the drive. Setting units are
determined by parameter o1-03.
Note: The value set to o1-03 is changed to 1 and the
unit is changed to percentage automatically
when A1-02 is set to 6 or 7.
Default: 0.00 Hz
Min.: 0.00
Max.: 400.00
<1>
<2>
205
d1-17
(0292)
Jog Frequency
Reference
Jog Reference
All Modes
Sets the Jog frequency reference. Setting units are determined
by parameter o1-03.
Default: 6.00 Hz
Min.: 0.00
Max.: 400.00
<1>
<2>
205
<1> Range upper limit is determined by parameters d2-01, Frequency Reference Upper Limit, and E1-04, Maximum Output Frequency.
<2> The value of o1-03 is changed to 1 and the unit is also changed to a percentage (%) when the control mode is set to CLV/PM or AOLV/PM.
B.6 d: Reference Settings
462