KSB Movitec VV04/05 [11/60] High pressure pumps

KSB Movitec VV015/05 [11/60] High pressure pumps
Fluid handled Movitec
Substance contained Max. per-
centage
T
max.
V VC VS LHS
[%] [°C] 13 14 15 16 18 13 14 15 16 18 23 13 14 15 16 18 17 19
Citric acid
≤ 25 +30 - - - - - - - - - - - - - - - -
Citric acid
≤ 10 +30 - - - - - - - - - - - - - - - -
Fuel
Diesel oil
≤ 100 +80 - - - - - - - - - - - - - - - -
Fuel oil
≤ 100 +80 - - - - - - - - - - - - - - - -
Kerosene (jet fuel)
≤ 100 +80 - - - - - - - - - - - - - - - -
Trisodium phosphate ≤ 4 +80 - - - - - - - - - - - - - - -
Water
Deionised water (fully
desalinated)
≤ 100 +140 - - -
12)
- - - - - - - - -
12)
-
Distilled water
≤ 100 +140 - - - - - - - - - - - - - - - - -
13)
Dealkalised water
≤ 100 +120 - - - - - - - - - - - - - - - -
Decarbonised water
≤ 100 +120 - - - - - - - - - - - - - - - -
Swimming pool water
(no brine)
≤ 100 +100 - - - - - - - - - - - - - - - - -
Permeate (osmosis)
≤ 100 +140 - - -
12)
- - - - - - - - -
12)
- -
Partly desalinated water
≤ 100 +120 - - - - - - - - - - - - - - - -
Fire-fighting water
≤ 100 +60 - - - - - - - - - - - -
Heating water in
accordance with VDI 2035
≤ 100 +100 - - - - - - - - - -
13)
Hot water treated in
accordance with
VdTüV 1466
≤ 100 +140
10)
- - -
12)
10)
- - -
12)
10)
10)
- - -
12)
-
13)
Boiler feed water to
VdTÜV 1466
≤ 100 +140
10)
- - -
12)
10)
- - -
12)
10)
10)
- - -
12)
-
13)
Condensate treated in
acc. with VdTÜV 1466
≤ 100 +140
10)
- - -
12)
10)
- - -
12)
10)
10)
- - -
12)
-
13)
Vapour condensate
(brewery)
≤ 100 +140
10)
- - -
12)
10)
- - -
12)
10)
10)
- - -
12)
- -
Cooling water
≤ 100 +100 - - - - - - - - - - - - - - -
Tap water
≤ 100 +60 - - - - - - - - - - - - - - -
Brewing water
≤ 100 +60 - - - - - - - - - - - - - - -
Ice water (brewery)
≤ 100 +60 - - - - - - - - - - - - - - -
Drinking water / tap
water
≤ 100 +60 - - - - - - - - - - - - - -
Hot water (brewery)
≤ 100 +60 - - - - - - - - - - - - - - -
Clean water
≤ 100 +60 - -
Brackish water
≤ 100 +15 - - - - - - - - - - - - - - - - -
Seawater
≤ 100 +15 - - - - - - - - - - - - - - - - -
Raw water
≤ 100 +60 - - - - - - - - - - - - - - -
Grey water, slightly
contaminated water
≤ 100 +60 - - - - - - - - - - - - - - -
River water
≤ 100 +60 - - - - - - - - - - - - - - -
Lake water
≤ 100 +60 - - - - - - - - - - - - - - -
Dam water
≤ 100 +60 - - - - - - - - - - - - - - -
Surface water
≤ 100 +60 - - - - - - - - - - - - - - -
Fresh water
≤ 100 +60 - - - - - - - - - - - - - - -
Barrier water
≤ 100 +70 - - - - - - - - - - - - - - -
Rinsing water
≤ 100 +70 - - - - - - - - - - - - - - -
Rainwater, with strainer
≥ 20 +60 - - - - - - - - - - - - - - -
Water-glycol mixture
≤ 100 +100 - - - - - - - - - - - - - - - - -
12)
≤ 120 °C, depending on the pressure classes
13)
≤ 120 °C
High-pressure Pumps
High-pressure In-line Pumps
Movitec
11

Содержание

Похожие устройства

Скачать