Kohler Command PRO CH740NG [22/88] Fuel system

Kohler Command PRO CH740NG [22/88] Fuel system
22
Fuel System
KohlerEngines.com 24 690 30 Rev. D
IMPCO Carburetor Components
G
C
H
F
A
D
E
B
D
C
B
A Venturi B Fuel Inlet
C
Idle Speed
Adjustment Screw
D Throttle Lever
E
Venturi Retaining
Screw
F
Load Block
(if equipped)
G
Idle Speed Clamp
Bracket Mounting
Screw
H
Clamp Brackets
(if equipped)
Nikki Carburetor Components
G
B
A
D
E
I
C
H
F
A
Rear Plug with
Sealing Washer
B Fuel Inlet
C
Choke Lever
Assembly
D Throttle Lever
E Plastic Bushing F
Idle Speed
Adjustment Screw
G Vacuum Port H
Transfer Chamber
Cover
I
Choke Plate/Shaft
Assembly
WARNING
Explosive Fuel can cause res and severe
burns.
If a gaseous odor is detected, ventilate area
and contact an authorized service technician.
LPG is extremely ammable and is heavier than air
and tends to settle in low areas where a spark or ame
could ignite gas. Do not start or operate this engine
in a poorly ventilated area where leaking gas could
accumulate and endanger safety of persons in area.
NG is extremely ammable, is lighter than air, and
rises. Do not start or operate this engine in a poorly
ventilated area where leaking gas could accumulate
and endanger safety of persons in area.
To ensure personal safety, installation and repair of
LPG/NG fuel supply systems must be performed only
by quali ed LPG/NG system technicians. Improperly
installed and maintained LPG/NG equipment could
cause fuel supply system or other components to
malfunction, causing gas leaks.
Observe federal, state and local laws governing LPG/
NG fuel, storage, and systems.