CITEL MSP-VM230-2P Инструкция по установке онлайн

Mounting and bonding by wireMounting and bonding with braketMounting and bonding on DIN-rail
Installation - Grounding MaintenanceDimensions
Technical Data
Application example
MSP-VM12/R
12 Vac / 15 Vdc
24 Vac / 30 Vdc
50 Vac / 65 Vdc
120 Vac / 150 Vdc
230 Vac / 255 Vdc
Degree of protection IP20
MSP-VM24/R
MSP-VM120/R
MSP-VM230/R
MSP-VM12
MSP-VM24
MSP-VM230
MSP-VM24-2P
MSP-VM12-2P
MSP-VM48-2P
MSP-VM120-2P
MSP-VM230-2P
MSP-VM24-2P-V12
P/N
6500 ft max.
2000 m ma
x.
-40/+185°F max.
-40/+85°C max.
indoor use only
and replace
defective MSP-VM
INSTALLATION INSTRUCTIONS -
N121013c
NOTICE D'INSTALLATION
NOTICIA DE INSTALACIÓN - INSTALLATIONSHINWEISE
ISTRUZIONI PER L'INSTALLAZIONE
INSTRUCOES DE INSTALACAO - MONTÁŽNÍ NÁVOD
РУКОВОДСТВО ПО МОНТАЖУ - 安装指导书
MSP-VM Series
37
55
64
PE
Towards equipement
to be protected
Example
equipment
BNC cable or RJ45 connector
2-pair or 1-pair signal
Power supply
X
Clip on
symmetrical
DIN rail
DIN-rail
Bracket
1
2
3
press cable
shoe together
Dataline surge protector
Parafoudres pour lignes de données
Proteccion para lineas datosli
Überspannungsschutz für datentechnik
Protezione per linee datii
Protector de Surto para linha de datos
MSP-VMxx/R MSP-VMxx MSP-VMxx-2P
MSP-VMxx-2P-V12
X
WIRING
LOCATION : SPDs should preferably be placed at the entrance of the installation and as close as possible to the sensitive equipment (<< 10 m).
GROUNDING : to reduce the residual voltages, the connection of the protector to the bounding network must be as short as possible (less than 50cm)
and has a proper cross section (at least 12AWG).
WIRING : The SPD is connected in series on the lines. External lines must be connected on “LINE” side. Equipment to be protected must connected on “EQUIPt” side.
- Power terminal wire range : 28-12AWG. And data line terminal wire range: 28-16AWG.
- Video connector : BNC or RJ45
Un / Uc
Содержание
- Dataline surge protector parafoudres pour lignes de données proteccion para lineas datos li überspannungsschutz für datentechnik 1
- Installation grounding maintenance dimensions 1
- Installation instructions 1
- N121013c 1
- Noticia de instalación installationshinweise istruzioni per l installazione instrucoes de instalacao montážní návod руководство по монтажу 安装指导书 1
- Protezione per linee dati i protector de surto para linha de datos 1
- Technical data application example 1
- Towards equipement to be protected 1
- Advertencia de seguridad 2
- Atencion 2
- Attention 2
- Attenzione 2
- Avisos importantes 2
- Avvertenze importanti 2
- Bezpečnostní pokyny 2
- Consignes de securite 2
- It es pt 2
- Rus varování 2
- Safety instructions 2
- Sicherheitshinweise 2
- Warnung 2
- Внимание 2
- Меры безопасности 2
- 中文 2
- 安全须知 2
Похожие устройства
- CITEL MSP-VM24-2P Инструкция по установке
- CITEL MSP-VM12/R Инструкция по установке
- CITEL VM120-DIN Инструкция по установке
- CITEL VM230-DIN Инструкция по установке
- CITEL LSC-A Инструкция по установке
- CITEL LSC-A/DIN Инструкция по установке
- CITEL MSB10-120 Инструкция по установке
- CITEL MSB10-24 Инструкция по установке
- CITEL MSB10-400 Инструкция по установке
- CITEL MSB10C-400 Инструкция по установке
- CITEL MSB10V-120 Инструкция по установке
- CITEL MSB10V-400 Инструкция по установке
- CITEL MSB6-24/LD Инструкция по установке
- CITEL MSB6-400 Инструкция по установке
- CITEL MSB6-400/LD Инструкция по установке
- Camelion M145-SL C01 Инструкция по эксплуатации
- Camelion M217-DL C01 Инструкция по эксплуатации
- Camelion M282-DL C01 Инструкция по эксплуатации
- Camelion Loft PL-426M C62 Инструкция по эксплуатации
- Camelion Loft PL-426M C65 Инструкция по эксплуатации