In order to retrieve measurement results again, press
the memory key M. Initially, the average value of the
last three blood pressure readings is displayed (Dis-
play ). Press the memory key M again to display the
latest measurements with date, time and graphic WHO
classification and to hear the values announced. You
can adjust the volume during the announcement by
pressing the volume key + and -.
•
You can clear the memory by pressing and holding +
and - simultaneously for 5 seconds after pressing the
memory key M and selecting the user.
•
If you wish to change the user memory, see “Select
memory”.
7. Error messages/troubleshooting
In case of faults, the _ message appears in the display.
Error messages may appear if:
•
systolic or diastolic pressure could not be measured
( or appears on the display)
•
systolic or diastolic pressure was outside the measure-
ment range ( or
Lo
appears on the display)
•
the cuff is fastened too tightly or loosely (
Er3
or
Er4
appears on the display)
•
the pump pressure is higher than 300 mmHg (
Er5
appears on the display)
•
pumping up takes longer than 160 seconds (
Er6
appears on the display)
•
there is a system or device error (
ErA
,
, Er7
or
Er8
appears on the display)
•
the batteries are almost empty .
In the above cases, you must repeat the measurement.
Make sure that the cuff tube is properly inserted and that
you do not move or talk.
Re-insert the batteries if necessary, or else replace
them.
Technical alarm – description
Should the recorded blood pressure (systolic or diasto-
lic) lie outside the limits specified in the section “Techni-
cal specifications”, the technical alarm will appear on the
display indicating either “
” or “
Lo
”. In such cases, you
should seek medical assistance and check the accuracy
of your procedure.
The limit values for the technical alarm are factory set
and cannot be adjusted or deactivated. These alarm limit
values are accorded second priority under the standard
IEC 60601-1-8.
The technical alarm is a non-locking alarm and must not
be reset. The signal shown on the display will disappear
automatically after about 8 seconds.
Содержание
- Deutsch 2
- Kennenlernen 2
- Wichtige hinweise 2
- Gerätebeschreibung 6
- Messung vorbereiten 6
- Blutdruck messen 7
- Fehlermeldung fehlerbehebung 10
- Messwerte speichern abrufen und löschen 10
- Gerät reinigen und aufbewahren 11
- Technische angaben 12
- Garantie 13
- English 14
- Getting to know your instrument 14
- Important information 14
- Loudspeaker 17
- Unit description 17
- Prepare measurement 18
- Measuring blood pressure 19
- Saving retrieving and deleting results 21
- Error messages troubleshooting 22
- Cleaning and storing the instrument 23
- Technical details 23
- Français 25
- Premières expériences 25
- Remarques importantes 25
- Description de l appareil 29
- Préparation à la mesure 29
- Mesure de la tension artérielle 30
- Enregistrement appel et suppression des valeurs mesurées 33
- Message d erreur suppression des erreurs 33
- Nettoyage et rangement de l appareil 34
- Données techniques 35
- Conocer el aparato 37
- Español 37
- Indicaciones importantes 37
- Descripción del aparato 41
- Preparar la medición 41
- Medir la presión sanguínea 43
- Almacenar activar y borrar valores de medición 45
- Aviso de fallas eliminación de fallas 46
- Limpiar y guardar el aparato 46
- Os avisos de error pueden aparecer en los sigu ientes casos 46
- Datos técnicos 47
- Важные указания 49
- Ознакомление 49
- Русский 49
- Описание прибора 53
- Подготовка к измерению 53
- Измерение кровяного давления 55
- Сообщения о неисправностях устранение неисправностей 58
- Сохранение вызов и удаление результатов измерения 58
- Очистка и хранение прибора 59
- Технические данные 59
- Гарантия 61
- Electromagnetic compatibility information 63
- Table 1 for all me equipment and me systems 63
- Table 2 for all me equipment and me systems 64
- Table 3 for me equipment and me systems that are not life supporting 65
- Table 4 for me equipment and me systems that are not life supporting 67
Похожие устройства
- HP Pavilion dv7-6b04er QJ395EA Инструкция по эксплуатации
- Samsung GE102WR Инструкция по эксплуатации
- Beurer BC 44 Инструкция по эксплуатации
- HP Pavilion dv6-6b56er A2Z12EA Инструкция по эксплуатации
- Samsung GE87KR Инструкция по эксплуатации
- Beurer BC 58 Инструкция по эксплуатации
- Sony VPC-CB2S1R/B Black Инструкция по эксплуатации
- Samsung GE87HR Инструкция по эксплуатации
- Beurer BC 31 Инструкция по эксплуатации
- HP 4330s LW813EA Инструкция по эксплуатации
- Samsung GE83UR Инструкция по эксплуатации
- Beurer BM 44 Инструкция по эксплуатации
- HP Pavilion dv7-6b53er A2T85EA Инструкция по эксплуатации
- Beurer BM 58 Инструкция по эксплуатации
- Samsung G2739NR Инструкция по эксплуатации
- Sony VPC-CA3S1R/R Red Инструкция по эксплуатации
- Beurer BM 70 Инструкция по эксплуатации
- Samsung G271XNR Инструкция по эксплуатации
- Sony VPC-CA3S1R/L Blue Инструкция по эксплуатации
- Samsung G2719NR Инструкция по эксплуатации