Figure 9. Reset button for overheat protector
Abbildung 9. Rücksetzknopf des Überhitzungsschutzes
3.5. Resetting the Overheat Protector
If the temperature of the sauna room becomes
dangerously high, the overheat protector will
permanently cut off the supply of the heater. The
overheating protector can be reset after the heater
has cooled down.
Location of the reset button has been marked in
the heater’s type label. The overheating protector
can be reset by pressing through the label with
a screwdriver (Figure 9). Only persons authorised
to carry out electrical installations can reset the
overheat protector.
Prior to pressing the button, the cause of the fault
must be found.
Are the stones crumbled and pressed together?
Has the heater been on for a long time while
unused?
Is the sensor of the thermostat out of place or
broken?
Has the heater been banged or shaken?
3.5. Zurückstellen des Überhitzungsschutzes
Wenn die Temperatur in der Saunakabine gefährlich
stark ansteigt, unterbricht der Überhitzungsschutz
die Stromzufuhr zum Ofen permanent. Der Überhit-
zungsschutz kann nach Abkühlen des Ofens zurück-
gesetzt werden.
Die Lage der Reset-Taste für den Überhitzungss-
chutz ist am Typenschild des Ofens markiert.
Dieser kann mit einem schmalen Schraubenzieher
durch das Typenschild zurückgesetzt werden (Ab-
bildung 9). Nur eine zu Elektroinstallationen befugte
Person darf diese Arbeit ausführen.
Vor Betätigung des Knopfes muß die Ursache der
Fehlfunktion festgestellt werden:
Sind die Steine im Saunaofen verkeilt oder spröde?
War der Saunaofen lange angeschaltet und
wurde nicht benutzt?
Ist der Thermostatfühler an einem falschen
Platz oder defekt?
War der Saunaofen starken Stößen ausgesetzt?