8. REPAIR
The authorized repair workshops are the only ones which can repair the motor in bad state. The meters must be cleaned and dried up before its
delivery to be repaired.
When ordering spare parts, make sure it is given the correct code of the spare part, the manufacturing date and the pump serial number. This will
guarantee the correct supply of the requested spare part.
1. All the products manufactured by TOT COMERCIAL SA have a WARRANTY of 12 (twelve) months from their purchase, against any manufacturing
defect.
2. TOT COMERCIAL SA guarantees, in the warranty period, the change/the devolution of the defective part or product. This material must be sent
with prepaid freight to our factory or any appointed technical service. After our technical inspection, it will be determined whether the responsibility
is from the manufacturer, the user, the installer or the delivery transport.
3. The warranty does not cover: the inadequate use, the negligence, the corrosion, the abuse, the manipulation or the wrong installation of the
products, the use of non-original spare parts or not concerning to the specifi c model. All the manufactured and/or commercialized equipment
must be installed according to the manufacturer’s instructions.
4. The accessories and the products not manufactured by TOT COMERCIAL SA are liable for their original manufacturer’s warranty.
5. Because of the constant innovations and development, TOT COMERCIAL SA reserves the right to modify the specifi cations of its products and
publicity, without prior notifi cation.
9. PROBLEM GUIDE
BREAKDOWN POSSIBLE CAUSE SOLUTION
The litres are passing, but the
numeration does not count.
- there are impurities on the measuring
chamber.
- clean the measuring chamber (10). If it is used to transfer AdBlue/DEF,
please clean with demineralized water (preferentially in hot).
Loss of liquid - Allen screws loose
- because of the overpressure the joint has
been moved.
- joint breaking
- tighten up the Allen screws (15).
- replace the joint (9 or 13).
- replace the joint (9 or 13).
The total or partial numeration
does not point correctly.
- numeration breaking - replace the numeration (22).
You read more or less litres than
those supplied.
- calibration failure
- the minimum fl ow is not respected.
- calibrate the meter according to the section 6.
- the minimum supply fl ow must be 15 l/min to assure a trustworthy measurement.
Low fl ow rate - impurities on the measuring chamber
- dirtiness on the red adaptor
- clean the measuring chamber (10).
- clean the inner sieve.
It counts too quick or too slow. - bad calibration
- air inlet
- blocked gears
- the minimum fl ow is not respected.
- calibrate the meter according to the section 6.
- look for and repair the possible losses or air inlets on the system.
- clean and replace the gears (23, 26, 27 or 33).
- the minimum supply fl ow must be 15 l/min to assure a trustworthy measurement.
10. WARRANTY
11. EU CONFORMITY DECLARATION
Manufacturer: TOT COMERCIAL SA - Partida Horta d'Amunt s/n - Apartado Correos nº 149 - 25600 BALAGUER (Lleida) SPAIN
STATES under its own responsibility the supplied product:
VOLUMETRIC MECHANICAL METER· Make: GESPASA
Model: MG-80 · MGI-80 · MG-80V · MGI-80V
is in accordance with the following legislative and/or normative documents
DIRECTIVES
Nr. and issued rules date
2006/42/UE: Safety of machinery EN-ISO 12100:2012
- This Declaration will lose its validity in case that any modifi cation is made without the explicit manufacturer's consent.
Balaguer, November 2017
Andreu Pané