Troubleshooting
Fault Cause Remedy
Motor does not start > Fuse in mains plug has blown. Reset the fuse.
> Overload protection switch has
tripped.
Switch off the vacuum cleaner
and allow it to cool for approx. 5
minutes. If it can not be started
again, contact the Makita
service department.
Motor does not run in
automatic mode
> Power tool is defective or not
connected properly.
Check that the power tool
works or that the plug is
inserted correctly.
Reduced suction power > Suction power selected with
suction power control is to low.
Set suction power in
accordance with section
“Suction power control”.
> Hose diameter does not
correspond with switch
position.
Set correct switch position for
hose diameter.
> Clogged suction hose/nozzle. Clean suction hose/nozzle.
> Seal/tank rim between the
upper section of the cleaner
and the dirt tank is dirty/
defective.
Clean/replace seal.
> Filter bag is full. See section “Replacing the
filter bag”.
> Filter element is clogged. See section “Cleaning the filter
element” and “Replacing the
filter element”.
No suction power during wet
cleaning
> Tank is full (floater closes the
suction opening).
Switch off the cleaner. Empty
the tank.
Voltage fluctuations > Impedance of power supply is
too high.
Use a suitable extension cord
(see section “Technical data”).
Connect the cleaner to another
socket closer to the fuse box.
Voltage fluctuations over 7
% should not occur if the
impedance at the transfer point
is 0.15 .