Stihl GHE 105.0 [41/492] Technical specifications

Stihl GHE 105.0 [41/492] Technical specifications
39
DEFRNLITESPTNOSVFIDAPLSLSKHU EN
0478 201 9915 A - EN
Name and address of relevant, named
location:
TÜV Rheinland LGA Products GmbH
Tillystraße 2
D-90431 Nürnberg
Compilation and storage of technical
documentation:
Sven Zimmermann
STIHL Tirol GmbH
The year of manufacture and machine
number appear on the rating plate of the
machine.
Measured sound power level:
100.8 dB(A)
Guaranteed sound power level:
104 dB(A)
Langkampfen,
2019-01-02 (YYYY-MM-DD)
STIHL Tirol GmbH
p.p.
Head of Design
* Caution!
In the case of mains fuses of less than
16 A, these may be tripped during start-
up or in the case of high load operation
of the machine.
17.1 REACH
REACH is an EC Directive for the
registration, evaluation, authorisation and
restriction of chemicals.
Information on compliance with the
REACH Directive (EC) No. 1907/2006 is
available from www.stihl.com/reach.
Fault:
Motor does not start
Possible cause:
Motor overload protection activated
–No mains voltage
Electric cable, plug, plug connector or
switch defective
Fuse in UK plug damaged (only applies
to machines for UK)
Feed chute not properly closed - safety
cut-off switch actuated (safety interlock)
Blade disc blocked
Locking device is not reset
Remedy:
Allow machine to cool down ( 8.6)
Check power cable and fuse
# ( 10.1)
Check cable, plug, connector and
switch and replace if necessary (by
electrician) # ( 10.1)
Replace fuse #
Close feed chute properly and tighten
screws ( 11.3)
17. Technical specifications
GHE 105.0
Power 2200 W
Amperage rating 9.8 A
Rated voltage 230 V
Frequency 50 Hz
Speed 2800 rpm
Fuses 16 A*
Protection class I
Type of protection Splash proof
(IPX4)
Operating conditions P40
40 s load time
60 s idle time
Tightening torque
Bolt
Blade disc
25 Nm
Tightening torque
Bolt
Reversible blade
10 Nm
L/W/H 77/48/97 cm
Weight 19 kg
19 kg (CH)
20 kg (GB)
Sound emissions:
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
WAd
104 dB(A)
In accordance with Directive 2006/42/EC:
Sound pressure level
at workplace L
pA
93 dB(A)
Uncertainty K
pA
3dB(A)
GHE 105.0
18. Troubleshooting
# If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.

Содержание