Ridgid LM-100 micro 36158 [12/318] Measurements

Ridgid LM-100 micro 36158 [12/318] Measurements
micro LM-100 Laser Distance Meter
Ridge Tool Company
10
Continuous Measurement, Max and Min
Measurement
1. Press and Hold Continuous Measurement Button to enter
the continuous measurement mode. In continuous measure-
ment mode, the measured value is updated approximately
every 0.5 seconds in the third line. The corresponding mini-
mum and maximum values are displayed dynamically in the
first and second line.
2. Press and Hold either ON/Measurement Button or Clear/-
Power OFF Button to stop taking continuous measure-
ments. The device automatically stops after 100 continuous
measurements.
Adding/Subtracting Measurements
1. Press Addition Button to add the next measurement to the
previous one.
2. Press Subtraction Button to subtract the next measurement
the previous one.
3. Press Clear/Power OFF Button to cancel the last action.
4. Press Clear/Power OFF Button again to return to taking
single measurements.
Area Measurement
1. Press Area/Volume Button . The symbol appears in the
display. The distance to be measured will flash in the symbol.
2. Press ON/Measurement Button to take the first measure-
ment (e.g. length).
3. Press ON/Measurement Button again to take the second
measurement (e.g. width).
4. The result of the area calculation is displayed in the third line;
the individually measured values are displayed in lines 1 and 2.
Reviewing the Last 20 Measurements
Press the Memory Button to review the last twenty measure-
ments or calculated results, shown in reverse order. Use the Addi-
tion or Subtraction Buttons to move through these records.
Clearing Data From Memory
Press and Hold the Memory Button and Press and Hold the
Clear/Power Button Key at the same time to clear all data in the
memory.
Backlighting the Display
Press the Backlight/Unit Change Button to turn the display back-
light ON or OFF.
Measurements
The RIDGID micro LM-100 Laser Distance Meter has a measuring
range of 50m (164') maximum. Use in bright sunlight may decrease
the range of the meter. The reflective properties of the surface may
also decrease the range of the meter.
Measurement errors can occur when measuring to clear, semi-per-
meable or high gloss/reflective surfaces such as colorless liquids
(e.g. water), glass, Styrofoam, mirrors, etc. Applying a commercially
available laser target plate to the surface may allow more accurate
measurements.
Do not aim the laser at the sun. This can damage the
meter.
Single Distance Measurement
1. Press ON/Measurement Button to activate the laser. Press
ON/Measurement Button again to take a measurement.
2. The measured value is displayed immediately.
NOTICE