Ridgid LM-100 micro 36158 [15/318] Battery disposal

Ridgid LM-100 micro 36158 [15/318] Battery disposal
micro LM-100 Laser Distance Meter
Ridge Tool Company
13
For EC Countries: Do not dispose of electrical equip-
ment with household waste!
According to the European Guideline 2002/96/EC for
Waste Electrical and Electronic Equipment and its imple-
mentation into national legislation, electrical equipment
that is no longer usable must be collected separately and disposed
of in an environmentally correct manner.
Battery Disposal
For EC countries: Defective or used batteries must be recycled ac-
cording to the guideline 2006/66/EEC.
Contact Ridge Tool Technical Services Department at rtctechser-
vices@emerson.com, or in the U.S. and Canada call (800) 519-
3456.
For troubleshooting suggestions, please refer to the troubleshoot-
ing guide on page 13.
Disposal
Parts of the micro LM-100 Laser Distance Meter contain valuable
materials and can be recycled. There are companies that special-
ize in recycling that may be found locally. Dispose of the com-
ponents in compliance with all applicable regulations. Contact your
local waste management authority for more information.
204
208
209
252
253
255
Calculation error.
Received signal too weak, measurement time too
long, Distance >50m.
Received signal too strong. Target too reflective.
Temperature too high.
Temperature too low.
Hardware error.
Repeat procedure.
Use target plate.
Use a commercially available target plate.
Cool down instrument.
Warm up instrument.
Power the unit OFF then ON, if the symbol still ap-
pears, please contact technical support.
CODE CAUSE CORRECTIVE MEASURE