BLOWER OPERATION Observe all applicable accident prevention regulations STARTING Move at least 3 m away from the place of refueling Place the blower on an open area of ground taking care that the air flow does not blow objects Make sure that this area is clear of combustible materials 1 When the engine is cold left stopped for more than 5 minutes or when fuel is added to the engine 1 Push the l O switch 1 to I position 2 Give a gentle push on the primer pump repeatedly 7 10 times until fuel comes into the primer pump 2 3 Close the choke lever fully by moving it to the IXI position 3 4 Lock the throttle lever in the start up position as follows Squeeze the throttle lever 4 fully Then push the lock button 5 Release the throttle lever while pushing the lock button 5 Place the blower on the ground Hold the handle with your left hand and give several strong pulls to the starter by your right hand 6 After the engine is started open the choke lever fully by moving it gradually to the I 4 I position 7 Release the throttle lever fully NOTE The throttle lever is unlocked when squeezing it slightly 2 Restarting immediately after the engine has stopped 1 Push the l O switch 1 to I position 2 Give a gentle push on the primer pump repeatedly 7 10 times until fuel comes into the primer pump 2 3 Open the choke lever fully by moving it to the I f I position 3 4 Leave the throttle lever fully released 5 Place the blower on the ground Hold the handle with your left hand and give several strong pulls to the starter by your right hand STOPPING Release the throttle lever fully and when the engine rpm has lowered push the l O switch to O position Engine will stop 8