Makita RBL250 [9/15] Idle adjustment

IDLE ADJUSTMENT If engine stops while idling turn the idle adjusting screw 1 clockwise until the engine runs smoothly SERVICING INSTRUCTIONS CAUTION Before doing any work on the blower always switch off the motor and pull the plug caps off the spark plugs see Checking the spark plugs page 12 Always wear protective gloves To ensure a long service life and to avoid any damage to the equipment the following servicing operations should be performed at regular intervals DAILY CHECKUP AND MAINTENANCE Before operation check the machine for loose screws or missing parts Every 8 hours Daily Before operation always check for clogging of the cooling air passage and the cylinder fins Clean them if necessary Every 8 hours Daily Perform the following maintenance daily after use Clean the blower externally and inspect for damage Clean the air filter When working under extremely dusty conditions clean the filter and blow out the cooling air passage and cylinder fins several times a day Check for proper functioning of the l O switch the throttle lever and the lock button CLEANING OF AIR CLEANER Every 8 hours Daily Remove the air cleaner cover Push the choke lever 1 to IXl position to prevent dirt particles from entering the carburetor Take out the sponge element 2 wash it in lukewarm water and dry it completely After cleaning put back the air cleaner cover 3 NOTE If there is excessive dust or dirt adhering to the air cleaner clean it every day A clogged air cleaner may make it difficult or impossible to start the engine increase the engine rotational speed 9