Daikin EWYQ007ACV3P [2/15] 1 technical specifications

Daikin EWYQ007ACV3P [2/15] 1 technical specifications
3
1
2
Hydronic Systems Chillers 2
Chillers R-410A EWYQ-ACV3P
2 Specifications
2-1 TECHNICAL SPECIFICATIONS
EWYQ005ACV3P EWYQ00 6ACV3P EW YQ007ACV3P
Capacity
(Eurovent
conditions
specified in
notes)
Cooling Minimum kW 4.01 4.01 4.01
Nominal kW 5.2 6.0 7.1
Maximum kW 5.2 6.0 7.1
Heating Minimum kW 4.09 4.09 4.09
Nominal kW 5.65 6.35 7.75
Maximum kW 6.83 8.13 8.73
Capacity
(conditions
specified in
notes)
Heating Minimum kW 4.5 4.5 4.5
Nominal kW 6.1 6.8 8.2
Maximum kW 7.27 8.58 9.18
Nominal input
(Eurovent
conditions
specified in
notes)
Cooling kW 1.89 2.35 2.95
Heating kW 1.97 2.24 2.83
Nominal input
(conditions
specified in
notes)
Heating kW 1.60 1.84 2.36
EER 2.75 2.55 2.41
COP (Eurovent conditions specified in notes) 2.87 2.83 2.74
COP (conditions specified in notes) 3.81 3.7 3.47
Casing Colour Ivory white
Material Polyester painted steel plate
Dimensions Unit Height mm 805
Width mm 1190
Depth mm 360
Unit with
pac king
Height mm 915
Width mm 1265
Depth mm 442
Weight Unit kg 100
Operating Weight kg 104
Gross weight kg 108
Water Heat
Exchanger
Type Brased plate
Filter Type Brass Y-str ainer
Diameter
per foratio
ns
mm 1 1 1
Minimum water volume in
the system
l 10 10 10
Water flow rate Min l/min 12 12 12
Nominal Water
Flow
Cooling l/min 14.9 17.2 20.4
Heating l/min 17.5 19.5 23.5
Insulation material Polyethylene foam
Model Quantity 1 1 1
Model ACH30-48
Air heat
exchanger
Type Tube type
Rows 2
Stages 32
Fin Pitch mm 1.8
Pump Type Water cooled
Quantity 1 1 1
Model RS 25/7 3 PL 130 3
Nominal static
height unit
Heating kPa 49.4 45.1 38.3
Heating kPa 44.5 40.3 30.7
Hydraulic
components
Antifreeze heater W 75
Expansion
vessel
Volume l 6
Pre-
pressure
bar 1
Water filter inch 1"
Safety valve bar 3