D - KIMWC00211-09EN - 12/58
Technical Data EWLD160~550DJYNN / EWLD160~550DJYNN + OPLR
TECHNICAL SPECIFICATIONS
EWLD-DJYNN / EWLD-DJYNN + OPLR
160 190 240 280 320
Capacity
(1
)
Cooling kW 160.6 189.0 244.0 270.4 315.5
Type Stepless
Capacity control
Minimum capacity % 25 25 25 25 12.5
Unit power input
(1
)
Cooling kW 45.4 54.3 65.9 74.6 90.6
EER
(1
)
3.54 3.48 3.70 3.62 3.48
Colour RAL7032
Casing
Material Galvanized and painted steel sheet
Height mm 1860 1860 1860 1860 1942
Width mm 1000 1000 1000 1000 1100
Dimensions Unit
Depth mm 3700 3700 3700 3700 4400
Unit
(2)
kg 1280 1280 1398 1398 2442
Weight
Operating Weight
(2)
kg 1337 1337 1516 1516 2560
Type Shell and tubes
Water volume l 60 56 123 123 118
Nominal water flow
rate
Cooling l/s 7.7 9.0 11.7 12.9 15.1
Nominal Water
pressure drop
Cooling kPa 44.6 59.7 41.0 49.3 57.4
Water heat exchanger
Evaporator
Insulation material Closet cell foam elastomer
Liquid receiver Volum 170 l
Type Semiermetici singola vite
Oil charge
(3)
l -- -- -- -- --
Compressor
Quantity 1 1 1 1 1
Sound Power
(4)
Cooling
dBA
88.0 88.0 88.0 88.0 88.0
Sound level
Sound Pressure
(4)
Cooling
dBA
69.7 69.7 69.7 69.7 69.7
Refrigerant type R134a R134a R134a R134a R134a
Refrigerant charge
(5)
kg -- -- -- -- --
Refrigerant circuit
N. of circuits 1 1 1 1 1
Piping connections Evaporator water inlet/outlet mm 88.9 88.9 88.9 88.9 88.9
Safety devices High pressure (pressure switch)
Safety devices Low pressure (pressure switch)
Safety devices Emergency stop
Safety devices High discharge temperature on the compressor
Safety devices Phase monitor
Safety devices Low pressure ratio
Safety devices High oil pressure drop
Safety devices Low oil pressure
Notes
(1)
Nominal cooling capacity and power input are based on: 12/7 °C entering/leaving evaporator water
temperature; 45 °C saturated discharge temperature at the compressor
(2)
Shipping and unit weight figures are related to the unit without sound proof cabinet
(3)
EWLD-DJYNN (+OPLR) version units with 3 l of oil precharged. Oil quantity must be defined by plant
designer only
(4)
Power and Pressure sound levels are referred to the unit without sound proof cabinet. Pressure
sound levels values with sound proof cabinet table at page 12
(5)
EWLD-DJYNN (+OPLR) version units are precharged with 5 kg of gas refrigerant. Refrigerant charge
must be defined by plant designer only