4.5.2. Function Key
Key [Channel] [Sweep] [MOD] [BURST] [SK] [TTL]: selects the ten functions of the instrument.
Key [COUNT]: selects the function of frequency counter.
Key [Utility]: sets the system parameters and exits remote control.
Key [Sine ] [Square ] [Ramp ] [Pulse ] [Noise ] [Arb ]: selects waveforms.
Key [CHA Output/Trigger] [CHB Output/Trigger]: Turns on or off the signal output of channel A & channel B and the
trigger output of channel A & channel B.
4.5.3. Soft Key
There are five blank soft keys at the right side of TFT display. They are used to select the various options under each
function.
4.5.4. Numeric Keypad
Key [0] [1] [2] [3] [4] [5] [6] [7] [8] [9]: for numeric input.
Key [.]: decimal point.
Key [-]: negative sign.
4.5.5. Unit Soft Key
There are five blank keys at the bottom side of TFT display. The definitions of these soft keys change according to the
characteristics of data. The input value has to be validated by pressing the unit soft key at the end of data input.
4.5.6. Direction Key
Key [LEFT] and [RIGHT]: cursor keys, used to add or subtract the digit on the cursor when tuning the rotary knob.
Key [UP] and [DOWN]: used to increase or decrease the frequency or amplitude of channel A.
4.6. Fundamental Operation
4.6.1. Function of Channel A
• Press key [Channel] to select “CHA Alone” function.
• Set the frequency of channel A: set frequency at 3.5kHz
• Select “Frequency” by the corresponding soft key, then press keys [3] [.] [5] and the soft key corresponding to [kHz].
• Adjust the frequency of channel A: press key [LEFT] or [RIGHT] to move the cursor left or right, and rotate the knob
left or right to decrease or increase the digits continuously for the coarse or fine adjustment of frequency. Apply the
same procedures for adjustments of other parameters.
• Set period of channel A: set a period of 25ms. Into the frequency menu, select “Period” by the corresponding soft
key, then press keys [2] [5] and the soft key corresponding to [ms].
• Set amplitude of channel A: set amplitude peak value at 3.2Vpp Into the frequency menu, select “Amplitude” by the
corresponding soft key, then press keys [3] [.] [2] and the soft key corresponding to [Vpp].
Содержание
Похожие устройства
- PEAKTECH PKT-P3365 Инструкция по эксплуатации
- PEAKTECH PKT-P3410 Инструкция по эксплуатации
- AXIOMET AX-DG1005AF Инструкция
- AXIOMET AX-DG1005AF Расширенная инструкция
- PEAKTECH PKT-P3442 Инструкция по эксплуатации
- AXIOMET AX-DG100-SOF Инструкция
- PEAKTECH PKT-P3443 Инструкция по эксплуатации
- AXIOMET AX-DG105 Инструкция
- AXIOMET AX-DG105 Расширенная инструкция
- PEAKTECH PKT-P3444 Инструкция по эксплуатации
- AXIOMET AX-EL600W120A Инструкция
- AXIOMET AX-EL600W120A Расширенная инструкция
- PEAKTECH PKT-P3445 Инструкция по эксплуатации
- PEAKTECH PKT-P3445 Технические характеристики
- AXIOMET AX-EL600W Инструкция
- AXIOMET AX-EL600W Расширенная инструкция
- AXIOMET AX-EL300W60A Инструкция
- AXIOMET AX-EL300W60A Расширенная инструкция
- AXIOMET AX-EL300W Инструкция
- AXIOMET AX-EL300W Расширенная инструкция