AXIOMET AX-903 Расширенная инструкция онлайн [5/6] 528182
![AXIOMET AX-903 Расширенная инструкция онлайн [5/6] 528182](/views2/1665422/page5/bg5.png)
5
Detecting Live Wires
The Live Wire Detection feature is always on and the “Live Wire” icon will be displayed on the LCD.
When a Live Wire is detected, the red live wire LED indicator will be on. Static electricity charges
that can develop on drywall and other surfaces will spread the voltage detection area many inches
to each side of the actual electrical wire. To aid in locating the wire position, scan holding the unit
1/2 inch away from the wall surface or place your other hand on surface approximately 12 inches
from sensor.
Warning: shielded wires or live wires in metal conduits, casings, metallized walls or thick,
dense walls will not be detected. Always turn AC power off when working near wiring.
The unit is designed to detect 110 volts (for USA version) and 230 volts for (European version) AC in
live electrical wires. It will also detect the presence of live wires having greater than 230 volts.
Adjustment Feet
The adjustment feet allow the leveling of the Laser line on the horizontal or vertical surfaces.
Cautions on Operating
You should always use caution when nailing, cutting or drilling in walls, ceilings and floors that may
contain wiring or pipes near the surface.
Shielded, dead or non-powered wiring will not be detected as live wires.
Always remember that studs or joists are normally spaced 16 inches or 24 inches apart and are
1-1/2 inches in width. To avoid surprises, be aware that anything closer together or of a different
width may be an additional a stud, joist or firebreak.
When working near AC electrical wires, always turn off the power.
Operating Tips
IMPORTANT SAFETY NOTICE
Insure proper detection of live wires ALWAYS hold the unit in the handle area only. Grasp between
fingers and thumb while maintaining contact with your palm.
Conventional Construction
Doors and windows are commonly constructed with additional studs and headers for added stability.
The unit detects the edge of these double studs and solid headers and emits and holds an audio
signal as it crosses over them.
Surface Differences
Wallpaper—there will be no difference in the function of the stud sensor on surfaces covered with
wallpaper or fabric unless the coverings contain metallic foil or fibers. Plaster and Lath — unless the
plaster and lath is exceptionally thick or has metal mesh in it, there will be no problem with the
unit functioning properly. Ceiling or Textured Surfaces—When dealing with a rough surface such as
a sprayed ceiling, use a piece of cardboard when scanning the surface. Run through the calibration
Содержание
Похожие устройства
- Mipro ACT-707 Инструкция по эксплуатации
- AXIOMET AX-T2090 Инструкция
- AXIOMET AX-T2090 Расширенная инструкция
- Mipro ACT707D Инструкция по эксплуатации
- Mipro ACT707DE Инструкция по эксплуатации
- Mipro ACT707HM Инструкция по эксплуатации
- Mipro ACT707S Инструкция по эксплуатации
- Mipro ACT707SE Инструкция по эксплуатации
- Mipro ACT707TM Инструкция по эксплуатации
- Mipro ACT81 Инструкция по эксплуатации
- Mipro ACT82 Инструкция по эксплуатации
- AXIOMET AX-T02 Расширенная инструкция
- AXIOMET AX-T02 Инструкция
- AXIOMET AX-T03 Инструкция
- AXIOMET AX-T03 Расширенная инструкция
- Mipro ACT8H Инструкция по эксплуатации
- AXIOMET AX-T01 Расширенная инструкция
- AXIOMET AX-T01 Инструкция
- Mipro ACT8T Инструкция по эксплуатации
- Mipro AD-808 Инструкция по эксплуатации