Safety Summary
The following safety precautions apply to both operating and maintenance personnel and must
be followed during all phases of operation, service, and repair of this instrument.
Before applying power to this instrument:
Read and understand the safety and operational information in this manual.
Apply all the listed safety precautions.
Verify that the voltage selector at the line power cord input is set to the correct line
voltage. Operating the instrument at an incorrect line voltage will void the warranty.
Make all connections to the instrument before applying power.
Do not operate the instrument in ways not specified by this manual or by B&K Precision.
Failure to comply with these precautions or with warnings elsewhere in this manual violates the
safety standards of design, manufacture, and intended use of the instrument. B&K Precision
assumes no liability for a customer’s failure to comply with these requirements.
Category rating
The IEC 61010 standard defines safety category ratings that specify the amount of electrical
energy available and the voltage impulses that may occur on electrical conductors associated
with these category ratings. The category rating is a Roman numeral of I, II, III, or IV. This rating
is also accompanied by a maximum voltage of the circuit to be tested, which defines the voltage
impulses expected and required insulation clearances. These categories are:
Category I (CAT I): Measurement instruments whose measurement inputs are not intended to
be connected to the mains supply. The voltages in the environment are typically derived from a
limited-energy transformer or a battery.
Category II (CAT II): Measurement instruments whose measurement inputs are meant to be
connected to the mains supply at a standard wall outlet or similar sources. Example
measurement environments are portable tools and household appliances.
Category III (CAT III): Measurement instruments whose measurement inputs are meant to be
connected to the mains installation of a building. Examples are measurements inside a
building's circuit breaker panel or the wiring of permanently-installed motors.
Category IV (CAT IV): Measurement instruments whose measurement inputs are meant to be
connected to the primary power entering a building or other outdoor wiring.
Содержание
- C series 5 ½ and 6 ½ digit multimeters 1
- Models 5492c 5492cgpib 5493c 5493cgpib 1
- User manual 1
- Safety summary 2
- Compliance statements 6
- Ce declaration of conformity 7
- Safety symbols 8
- Contents 9
- General information 11
- Operating environment 11
- Package contents 11
- Front panel overview 12
- Product dimensions 12
- Rear panel overview 13
- Getting started 14
- Input power and fuse requirements 14
- Check and or change fuse 15
- Carrying handle adjustment 16
- Front panel menu reference 17
- Front panel operation 17
- Change display mode 19
- Display 19
- Display label text 20
- Digit mask 21
- Probe hold function 21
- Basic measurements 22
- Dc voltage 22
- Screen capture and file transfer 22
- Ac voltage 24
- Dcv ratio 24
- Dc current 26
- Ac current 27
- Resistance 2w 2 wire 29
- Resistance 4w 4 wire 30
- Capacitance measurement 31
- Continuity 33
- Temperature test 34
- Frequency measurement 35
- Math functions 37
- Null operation 37
- Secondary measurement 37
- Statistics 37
- Db calculation 38
- Dbm calculation 38
- Percent 38
- Recall settings 39
- Save readings 39
- Save recall 39
- Save settings 39
- Power on 40
- Set the language 41
- Setting the buzzer and brightness 41
- Setting the date time 41
- Setting the format of the digital display 41
- System settings 41
- Interface 42
- Rs232 interface 42
- Rs232 interface operation 42
- Lan interface 45
- Usb device 45
- Usb host 45
- Usb interface 45
- Gpib bus 46
- Gpib interface 46
- General bus commands 48
- Setting the gpib address 48
- Setting through the interface 48
- Specifications 5492c 5492cgpib 49
- Specifications 5492c 5492cgpib 50
- Specifications 5493c 5493cgpib 51
- Specifications 5493c 5493cgpib 52
- Specifications 5493c 5493cgpib 53
- Supplementary specifications 5493c 5493cgpib 54
- Service information 55
- Limited three year warranty 56
Похожие устройства
- B&K PRECISION BK5493CGPIB Расширенная инструкция
- Fluke FLK-8808A Инструкция по эксплуатации
- Fluke FLK-8808A Инструкция язык en
- Fluke FLK-8808A Расширенная инструкция
- Fluke FLK-8808A/TL Инструкция по эксплуатации
- Fluke FLK-8808A/TL Инструкция язык en
- Fluke FLK-8808A/TL Расширенная инструкция
- Fluke FLK-8845A Инструкция язык en
- Fluke FLK-8845A Инструкция по эксплуатации
- Fluke FLK-8845A Расширенная инструкция
- Fluke FLK-8845A/SU Инструкция по эксплуатации
- Fluke FLK-8845A/SU Инструкция язык en
- Fluke FLK-8845A/SU Расширенная инструкция
- Fluke FLK-8846A Инструкция по эксплуатации
- Fluke FLK-8846A Расширенная инструкция
- Fluke FLK-8846A Инструкция язык en
- Fluke FLK-8846A/SU Инструкция по эксплуатации
- Fluke FLK-8846A/SU Расширенная инструкция
- Fluke FLK-8846A/SU Инструкция язык en
- Fluke FLK-116/323 Инструкция по эксплуатации