CHAUVIN ARNOUX CA-MINI-09 [3/12] Current clamp for ac current model mini 01
![CHAUVIN ARNOUX CA-MINI-01 [3/12] Current clamp for ac current model mini 01](/views2/1665988/page3/bg3.png)
Serie MN
Pinces ampèremetriques pour courant AC
Non-contractual document
906131102A - Ed 1
1.01 (1/1)
MINI series
Current clamp for AC current
Model MINI 01
To order Reference
AC current clamp model MINI 01 with operating manual P01105101Z
•
Output:
Double-insulated cable 1.5 m long, terminated
by 2 insulated elbowed male banana connectors
Ø4mm
•
Bandwidth:
48 Hz .. 500 Hz
•
Clamping capacity:
Cable Ømax 10mm
ELECTRICAL SPECIFICATIONS
•
Load impedance:
≤10 Ω
•
Maximum currents:
I <150 A permanent from 48 Hz .. 500 Hz
•
Infl uence of temperature:
≤0.2% per 10 °K
•
Infl uence of adjacent conductor:
≤2 mA / A at 50 Hz
•
Infl uence of conductor position in jaws:
≤0.1% at 50/60 Hz
•
Infl uence of frequency:
≤2% from 65 Hz to 500Hz
•
Maximum output voltage (secondary open):
30 V
(1) Conditions of reference: 23 °C ± 3 °K, 20 °C to 75% RH, sinusoidal signal with frequency of 48 Hz to 65 Hz, distortion factor <1% with no DC component, external DC magnetic fi eld <40A/m,
no external AC magnetic fi eld, no external conductor with circulating current, conductor centred for measurement, measurement instrument load impedance ≤10 Ω.
(2) With clamp closed.
(3) Vibrations expressed inmm peak, scanning of 1 octave/minute for 10 minutes on 3 axes.
MECHANICAL SPECIFICATIONS
•
Operating temperature:
-10 °C to +50 °C
•
Storage temperature:
-40 °C to +80°C
•
Relative humidity for operation:
From 0 to 85% RH with a linear decrease above
35°C
•
Operating altitude:
0 to 2,000 m
•
Casing protection rating (leakproofi ng):
IP40
(2)
(EN60529 Ed. 1992)
•
Drop test:
1.5 m (IEC68-2-32)
•
Shock resistance:
100 g / 6 ms / half-period (IEC68-2-27)
•
Vibration resistance
(3)
:
5-15 Hz (1.5 mm), 15-25 Hz (1 mm), 25-55 Hz
(0.25mm) (IEC68-2-6)
•
Self-extinguishing capability:
casing UL94 V2
•
Dimensions:
130 x 37 x 25mm
•
Weight:
approx. 180 g
•
Colour:
Black casing
SAFETY SPECIFICATIONS
•
Electrical safety:
Instrument with double insulation or
reinforced insulation between the primary,
the secondary and the grippable part located
under the guard as per EN 61010-1 Ed.2:2001,
EN 61010-2-031 Ed. 2002 & EN 61010-2-032
Ed.2003
- 600 V categoryIII, pollution degree 2
- 300 V category IV, pollution degree 2
•
Electromagnetic compatibility:
CE-certifi ed equipment compliant with standard
EN61326-1 (Ed. 97) + A1 (Ed. 98) + A2 (Ed. 01)
- Emission: stipulations for class B equipment
(domestic use).
- Immunity: stipulations for equipment used
intermittently on industrial sites.
Calibre
150 A AC
Sensitivity
1 mA / A (1000 / 1)
DESCRIPTION
Small and compact, the MINI 01 current clamp is the ideal
complement for any multimeter to measure AC currents in
low-power tertiary or industrial applications.
If there is a current in the conductor clamped, the
MINI 01 clamp is protected against overvoltages during
disconnection from the measurement instrument.
MAIN SPECIFICATIONS
(1)
Calibre 150 A
Measurement range 2 A .. 150 A
Accuracy of primary
current in%
≤2.5% + 0.15 A (load 1 Ω)
≤3% + 0.15 A (load 10 Ω)
Phase shift not specified
Output signal
1 mAAC / AAC (1000 / 1)
(150 mA for 150 A)
Содержание
- Ct_gb_mini_906121102a_ed1 pdf 1
- Current clamps for ac current 1
- Mini 100 series 1
- Mini series 1
- Pinces ampèremetriques pour courant ac 1
- Serie mn 1
- Current clamps for ac current 2
- Mini 100 series 2
- Mini series 2
- Pinces ampèremetriques pour courant ac 2
- Serie mn 2
- Current clamp for ac current model mini 01 3
- Description 3
- Electrical specifications 3
- Main specifications 3
- Mechanical specifications 3
- Mini series 3
- Pinces ampèremetriques pour courant ac 3
- Safety specifications 3
- Serie mn 3
- Current clamp for ac current 4
- Description 4
- Electrical specifications 4
- Main specifications 4
- Mechanical specifications 4
- Mini series 4
- Model mini 02 4
- Pinces ampèremetriques pour courant ac 4
- Safety specifications 4
- Serie mn 4
- Ac current clamp model mini 02 with operating manual p01105102z 5
- Current clamp for ac current model mini 02 5
- Curves at 50 hz 5
- Frequency response at 10 a 5
- Mini series 5
- Pinces ampèremetriques pour courant ac 5
- Serie mn 5
- To order reference 5
- Current clamp for ac current model mini 03 6
- Description 6
- Electrical specifications 6
- Main specifications 6
- Mechanical specifications 6
- Mini series 6
- Pinces ampèremetriques pour courant ac 6
- Safety specifications 6
- Serie mn 6
- Current clamp for ac current model mini 05 7
- Description 7
- Electrical specifications 7
- Main specifications 7
- Mechanical specifications 7
- Mini series 7
- Pinces ampèremetriques pour courant ac 7
- Safety specifications 7
- Serie mn 7
- Current clamp for ac current model mini 09 8
- Description 8
- Electrical specifications 8
- Main specifications 8
- Mechanical specifications 8
- Mini series 8
- Pinces ampèremetriques pour courant ac 8
- Safety specifications 8
- Serie mn 8
- Current clamp for ac current 9
- Description 9
- Electrical specifications 9
- Main specifications 9
- Mechanical specifications 9
- Mini 100 series 9
- Model mini 102 9
- Pinces ampèremetriques pour courant ac 9
- Safety specifications 9
- Serie mn 9
- Ac current clamp model mini 102 with operating manual p01106102 10
- Current clamp for ac current 10
- Curves at 50 hz 10
- Erreur 10
- Erreur rc 1 ohm 10
- Erreur rc 10 ohms 10
- Erreur rc 100 ohms 10
- Frequency response at 10 a 10
- Fréquence 10
- Hz 10 hz 100 hz 1000 hz 10000 hz 100000 hz 10
- Mini 100 series 10
- Model mini 102 10
- Phase rc 1 ohm 10
- Phase rc 10 ohms 10
- Phase rc 100 ohms 10
- Pinces ampèremetriques pour courant ac 10
- Serie mn 10
- To order reference 10
- Current clamp for ac current 11
- Description 11
- Electrical specifications 11
- Main specifications 11
- Mechanical specifications 11
- Mini 100 series 11
- Model mini 103 11
- Pinces ampèremetriques pour courant ac 11
- Safety specifications 11
- Serie mn 11
- 01 a 0 1 a 1 a 10 a 100 a 1000 a 12
- Ac current clamp model mini 103 with operating manual p01106103 12
- Courant primaire 12
- Current clamp for ac current 12
- Curves at 50 hz 12
- Erreur 400 hz 12
- Erreur 50 hz 12
- Erreur de mesure 12
- Erreur de phase 12
- Frequency response 12
- Mini 100 series 12
- Model mini 103 12
- Phase 400 hz 12
- Phase 50 hz 12
- Pinces ampèremetriques pour courant ac 12
- Serie mn 12
- To order reference 12
Похожие устройства
- CHAUVIN ARNOUX CA-MINI-102 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MINI-102 Расширенная инструкция
- CHAUVIN ARNOUX CA-MINI-102 Инструкция язык en
- CHAUVIN ARNOUX CA-MINI-102 Документация язык
- CHAUVIN ARNOUX CA-MINI-103 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MINI-103 Расширенная инструкция
- CHAUVIN ARNOUX CA-MINI-103 Инструкция язык en
- CHAUVIN ARNOUX CA-MINI-103 Документация язык
- CHAUVIN ARNOUX CA-MN71 Инструкция язык en
- CHAUVIN ARNOUX CA-MN71 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MN71 Расширенная инструкция
- CHAUVIN ARNOUX CA-MN73 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MN73 Расширенная инструкция
- CHAUVIN ARNOUX CA-MN73 Инструкция язык en
- CHAUVIN ARNOUX CA-MN77 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MN77 Инструкция язык en
- CHAUVIN ARNOUX CA-MN77 Расширенная инструкция
- CHAUVIN ARNOUX CA-MN93 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MN93 Инструкция язык en
- CHAUVIN ARNOUX CA-MN93 Расширенная инструкция