CHAUVIN ARNOUX CA-MINI-09 [5/12] Current clamp for ac current model mini 02
![CHAUVIN ARNOUX CA-MINI-02 [5/12] Current clamp for ac current model mini 02](/views2/1665988/page5/bg5.png)
Serie MN
Pinces ampèremetriques pour courant AC
Non-contractual document
906131102A - Ed 1
1.02 (2/2)
MINI series
Current clamp for AC current
Model MINI 02
(1) Conditions of reference: 23 °C ± 3 °K, 20 °C to 75% RH, sinusoidal signal with frequency of 48 Hz at 10 kHz, distortion factor <1%
with no DC component, external DC magnetic fi eld <40A/m, no external AC magnetic fi eld, no external conductor with circulating current,
conductor centred for measurement, measurement instrument load impedance ≤10 Ω.
(2) With clamp closed.
(3 Vibrations expressed inmm peak, scanning of 1 octave/minute for 10 minutes on 3 axes.
CURVES AT 50 HZ
Typical linearity error for loads of 1, 10, 30 and 100 Ω
FREQUENCY RESPONSE AT 10 A
Typical linearity error for loads of 1, 10, 30 and 100 Ω
Typical phase shift for loads of 1, 10, 30 and 100 Ω
Typical phase shift for loads of 1, 10, 30 and 100 Ω
To order Reference
AC current clamp model MINI 02 with operating manual P01105102Z
Содержание
- Ct_gb_mini_906121102a_ed1 pdf 1
- Current clamps for ac current 1
- Mini 100 series 1
- Mini series 1
- Pinces ampèremetriques pour courant ac 1
- Serie mn 1
- Current clamps for ac current 2
- Mini 100 series 2
- Mini series 2
- Pinces ampèremetriques pour courant ac 2
- Serie mn 2
- Current clamp for ac current model mini 01 3
- Description 3
- Electrical specifications 3
- Main specifications 3
- Mechanical specifications 3
- Mini series 3
- Pinces ampèremetriques pour courant ac 3
- Safety specifications 3
- Serie mn 3
- Current clamp for ac current 4
- Description 4
- Electrical specifications 4
- Main specifications 4
- Mechanical specifications 4
- Mini series 4
- Model mini 02 4
- Pinces ampèremetriques pour courant ac 4
- Safety specifications 4
- Serie mn 4
- Ac current clamp model mini 02 with operating manual p01105102z 5
- Current clamp for ac current model mini 02 5
- Curves at 50 hz 5
- Frequency response at 10 a 5
- Mini series 5
- Pinces ampèremetriques pour courant ac 5
- Serie mn 5
- To order reference 5
- Current clamp for ac current model mini 03 6
- Description 6
- Electrical specifications 6
- Main specifications 6
- Mechanical specifications 6
- Mini series 6
- Pinces ampèremetriques pour courant ac 6
- Safety specifications 6
- Serie mn 6
- Current clamp for ac current model mini 05 7
- Description 7
- Electrical specifications 7
- Main specifications 7
- Mechanical specifications 7
- Mini series 7
- Pinces ampèremetriques pour courant ac 7
- Safety specifications 7
- Serie mn 7
- Current clamp for ac current model mini 09 8
- Description 8
- Electrical specifications 8
- Main specifications 8
- Mechanical specifications 8
- Mini series 8
- Pinces ampèremetriques pour courant ac 8
- Safety specifications 8
- Serie mn 8
- Current clamp for ac current 9
- Description 9
- Electrical specifications 9
- Main specifications 9
- Mechanical specifications 9
- Mini 100 series 9
- Model mini 102 9
- Pinces ampèremetriques pour courant ac 9
- Safety specifications 9
- Serie mn 9
- Ac current clamp model mini 102 with operating manual p01106102 10
- Current clamp for ac current 10
- Curves at 50 hz 10
- Erreur 10
- Erreur rc 1 ohm 10
- Erreur rc 10 ohms 10
- Erreur rc 100 ohms 10
- Frequency response at 10 a 10
- Fréquence 10
- Hz 10 hz 100 hz 1000 hz 10000 hz 100000 hz 10
- Mini 100 series 10
- Model mini 102 10
- Phase rc 1 ohm 10
- Phase rc 10 ohms 10
- Phase rc 100 ohms 10
- Pinces ampèremetriques pour courant ac 10
- Serie mn 10
- To order reference 10
- Current clamp for ac current 11
- Description 11
- Electrical specifications 11
- Main specifications 11
- Mechanical specifications 11
- Mini 100 series 11
- Model mini 103 11
- Pinces ampèremetriques pour courant ac 11
- Safety specifications 11
- Serie mn 11
- 01 a 0 1 a 1 a 10 a 100 a 1000 a 12
- Ac current clamp model mini 103 with operating manual p01106103 12
- Courant primaire 12
- Current clamp for ac current 12
- Curves at 50 hz 12
- Erreur 400 hz 12
- Erreur 50 hz 12
- Erreur de mesure 12
- Erreur de phase 12
- Frequency response 12
- Mini 100 series 12
- Model mini 103 12
- Phase 400 hz 12
- Phase 50 hz 12
- Pinces ampèremetriques pour courant ac 12
- Serie mn 12
- To order reference 12
Похожие устройства
- CHAUVIN ARNOUX CA-MINI-102 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MINI-102 Расширенная инструкция
- CHAUVIN ARNOUX CA-MINI-102 Инструкция язык en
- CHAUVIN ARNOUX CA-MINI-102 Документация язык
- CHAUVIN ARNOUX CA-MINI-103 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MINI-103 Расширенная инструкция
- CHAUVIN ARNOUX CA-MINI-103 Инструкция язык en
- CHAUVIN ARNOUX CA-MINI-103 Документация язык
- CHAUVIN ARNOUX CA-MN71 Инструкция язык en
- CHAUVIN ARNOUX CA-MN71 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MN71 Расширенная инструкция
- CHAUVIN ARNOUX CA-MN73 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MN73 Расширенная инструкция
- CHAUVIN ARNOUX CA-MN73 Инструкция язык en
- CHAUVIN ARNOUX CA-MN77 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MN77 Инструкция язык en
- CHAUVIN ARNOUX CA-MN77 Расширенная инструкция
- CHAUVIN ARNOUX CA-MN93 Инструкция по эксплуатации
- CHAUVIN ARNOUX CA-MN93 Инструкция язык en
- CHAUVIN ARNOUX CA-MN93 Расширенная инструкция