CHAUVIN ARNOUX CA-PAC93 [12/20] Ac dc current clamp

CHAUVIN ARNOUX CA-PAC17 [12/20] Ac dc current clamp
Série MN
Pinces ampèremétriques pour courant AC
Non-contractual document
906200083 - Ed 1
12.05 (1/2)
PAC Series
AC/DC current clamp
DESCRIPTION
The PAC25 model accurately measures AC or DC currents by making use of the Hall effect
principle. This clamp with mV output is equipped with an automatic DC zero system and a
deactivatable Auto Power Off (APO) function. It can be powered by a standard mains power
pack via a Micro USB connector.
Bandwidth:
DC .. 30 kHz (-3 dB) (depending on current value)
Insertion impedance:
0.05 mΩ @ 400 Hz, 0.14 mΩ @ 1 kHz
Maximum currents:
3,000 A DC or 1,000 A AC permanent for a
frequency < 1 kHz (limitation proportional to the
reciprocal of one third of the frequency beyond that)
DC zero adjustment:
Automatic, by 40 - 60 mA increments
AC noise output:
≤ 1 mV peak-peak
Power supply:
9 V alkaline battery (NEDA 1604A, IEC 6LR61)
5 V DC Micro USB type B
Battery life:
50 hours typical
Consumption:
10 mA typical (battery)
31 mA typical (µUSB 5 V)
"ON" LED:
"Lit" = In operation & battery level OK
"Flashing" = remaining battery life < 4 hours
"Colour = green" = APO ON
"Colour = yellow" = APO OFF
"OL" LED:
Overload indication: current measured too high for
the calibre used
In uence of power supply voltage:
None
In uence of temperature:
≤ 3 % variation over the whole operating
temperature range
In uence of relative humidity:
≤ 0.5% from 10 % to 85 % RH at room
temperature
In uence of an adjacent conductor carrying a 50 Hz
alternating current, 23 mm away from the clamp:
< 10 mA/A
In uence of a 400 A/m external  eld @ 50 Hz:
< 1.3 A
In uence of the position of a Ø 20 mm conductor
in the jaws:
≤ 0.5 %
In uence of the frequency
(3)
:
10 Hz .. 400 Hz: ≤ 1 % of V
S
400 Hz .. 10 kHz: ≤ 3.5 % of V
S
10 kHz .. 30 kHz: see curve
Common mode rejection:
> 65 dB A/V @ 50 Hz
Remanence:
0 to 100 A DC: 2.8 A typical
0 to 200 A DC: 3.5 A typical
0 to 400 A DC: 5 A typical
0 to 800 A DC: 5.3 A typical
0 to 1,200 A DC: 5.7 A typical
0 to 1,400 A DC: 5.8 A typical
MECHANICAL SPECIFICATIONS
Maximum jaw opening:
39 mm
Clamping capacity:
Cables: Ø 39 mm
Ø 25.4 mm x 2
Busbars: 1 bar 50 x 12.5 mm
2 bars 50 x 5 mm or 31.5 x 10 mm
3 bars 25 x 8 mm
4 bars 25 x 5 mm
Output:
1.5 m double-insulated cable with male safety
plugs (4mm)
Dimensions:
236.5 x 97 x 44mm
Weight:
520 g with battery
Operating temperature:
-10 °C to +55 °C
Storage temperature:
-40 °C to +80 °C
Max. temperature of clamped conductor
(measured):
+90 °C (may spike at +110 °C)
Max temperature of jaws:
+80 °C
Relative humidity for operation:
0 to 85 % RH with a linear decrease above 35 °C
Operating altitude:
0 to 2,000 m
Enclosure ingress protection:
IP 40 (IEC 60529)
Fall height:
1 m (IEC 60068-2-32)
Self-extinguishing capability
UL94 V1
Colours:
Casing: dark grey
Jaws: red
SAFETY SPECIFICATIONS
Electrical:
Type A appliance with double or reinforced
insulation between the primary, the secondary
and the grippable part below the guard as per
IEC61010-1 & IEC 61010-2-032
- 600 V category III, pollution degree 2
- 300 V category IV, pollution degree 2
Electromagnetic compatibility (EMC):
Complies with IEC 61326-1: 2012 (portable
instrument)
Current
1,000 A AC
1,400 A DC
Output
1 mV/A
ELECTRICAL SPECIFICATIONS
Current calibre:
0.5 A AC .. 1,000 A AC (1,400 A peak) / 0.5 A DC .. 1,400 A DC
Output signal:
1 mV AC+DC / A AC+DC (1.4 V for 1,400 A)
Accuracy and phase shift
(1)
:
Primary current 0.5 A .. 3 A 3 A .. 100 A 100 A .. 200 A 200 A .. 800 A 800 A .. 1,000 A
1,000 A .. 1,400 A
(DC only)
Accuracy in %
of output signal
1.5% + 1 mV 1.5% + 1 mV 2.5% 2.5% 4% 5%
Phase shift
(2)
Not specified 1.5° 1.5° -
PAC25 model