Maintenance
WARNING: To avoid electrical shock, disconnect the meter from any circuit and turn OFF the
meter before opening the case. Do not operate the meter with an open case.
Cleaning and Storage
Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or
solvents. If the meter is not to be used for 60 days or more, remove the batteries and store them
separately.
Battery Replacement
CAUTION: Remove the meter from the conductor under test and switch the meter OFF
before opening the battery compartment.
1. Remove the screw that secures the rear battery compartment.
2. Remove the battery compartment cover.
3. Replace the 2 ‘AAA’ 1.5V batteries observing correct polarity.
4. Re-attach the battery compartment cover.
5. Secure the battery compartment with the screw.
Never dispose of used batteries or rechargeable batteries in household waste.
As consumers, users are legally required to take used batteries to appropriate
collection sites, the retail store where the batteries were purchased, or wherever
batteries are sold.
Disposal: Do not dispose of this instrument in household waste. The user is obligated
to take end-of-life devices to a designated collection point for the disposal of electrical
and electronic equipment.
Specifications
Function
Range
Resolution
Accuracy
DC Voltage
6V
0.001V
±(0.8% + 5 digits)
60V
0.01V
600V
0.1V
1000V
1V
Input impedance: 10MΩ; Overload protection: ± 1000V DC and AC
AC Voltage
6V
0.001V
± (1.0% + 8 digits)
(50/60Hz)
True rms
60V
0.01V
600V
0.1V
1000V
1V
Input impedance: 10M ohms; Overload protection: ± 1000V DC and AC
Содержание
- A true rms ac flexible clamp meter 3000a true rms ac flexible clamp meter 1
- Additional user manual translations available at www extech com 1
- Model ma3110 model ma3110 1
- User manual 1
- Features 2
- Introduction 2
- Precautions and preparations for measurements 3
- Safety information 3
- Warnings 3
- Cautions 4
- Per iec1010 overvoltage installation category 4
- Safety symbols that are typically marked on meters and instructions 4
- Description 5
- Display icons 5
- Meter description 5
- Automatic power off 6
- Data hold 6
- Low battery indication 6
- Meter power 6
- Operation 6
- Dc and ac voltage measurements 7
- Ac current measurements 8
- Resistance measurements 9
- Continuity measurements 10
- Diode measurements 11
- Capacitance measurements 12
- Battery replacement 13
- Cleaning and storage 13
- Maintenance 13
- Specifications 13
- Ma3110 en gb_v1 12 16 14
- Specifications tested under environmental conditions of rf field strength 3v m and frequency 30mhz 14
- Copyright 2016 flir systems inc 15
- General specifications 15
- Www extech com 15
Похожие устройства
- EXTECH EX650 Инструкция по эксплуатации
- EXTECH EX650 Документация
- EXTECH EX650 Инструкция EN
- EXTECH EX650 Расширенная инструкция
- EXTECH EX810 Инструкция по эксплуатации
- EXTECH EX810 Расширенная инструкция
- EXTECH EX810 Документация
- EXTECH EX810 Инструкция EN
- EXTECH MA440 Инструкция по эксплуатации
- EXTECH MA440 Инструкция EN
- EXTECH MA440 Расширенная инструкция
- EXTECH MA443 Инструкция по эксплуатации
- EXTECH MA443 Инструкция EN
- EXTECH MA443 Расширенная инструкция
- EXTECH MA61 Инструкция по эксплуатации
- EXTECH MA61 Инструкция EN
- EXTECH MA61 Расширенная инструкция
- EXTECH MA610 Инструкция по эксплуатации
- EXTECH MA610 Расширенная инструкция
- EXTECH MA610 Инструкция EN