14
AC Current
600.0A
0.1 A
±(1.0% + 8 digits)
3000 A
1 A
±(1.0% + 10 digits)
True rms AC measurements
Linearity: ± 0.2% of reading from 10% to 100% of range
Conductor position sensitivity: ± (2.0% +15dgts) with the measured conductor a distance from
the center > 25mm (1”)
External field influence: An increase of ± 1.5% of range max. The recommended distance for
conductors from the clamp probe sides is > 200mm. Accuracy is specified for measurements
made with the conductor at the center of the clamp field.
Frequency bandwidth for AC Current Measurements: 50/60Hz
Resistance
600 Ω
0.1 Ω*
±(1.0% + 5 digits)
6K Ω
0.001K Ω*
±(1.5% + 5 digits)
60K Ω
0.01K Ω*
600K Ω
0.1K Ω*
6M Ω
0.001M Ω*
60M Ω
0.01M Ω*
±(3.0% + 5 digits)
Overload protection: ± 350 V DC & AC
*This is the resolution when measuring a fixed resistance < 90% of the range. The resolution
decreases by a factor of 10 when the measured resistance is > 90% of the range.
Capacitance
6nF
0.001 nF
±(3.0% + 10 digits)
60nF
0.01 nF
600nF
0.1 nF
6uF
0.001 uF
60uF
0.01 uF
600uF
0.1 uF
Overload Protection: ± 30 V DC & AC (Always discharge capacitors before testing)
Continuity
Visual and audible beeper alert when resistance is < 20 Ω
Diode
Short/Open, Good/Defective tests
Specifications tested under environmental conditions of RF field strength < 3V/M and frequency < 30MHz
Содержание
- A true rms ac flexible clamp meter 3000a true rms ac flexible clamp meter 1
- Additional user manual translations available at www extech com 1
- Model ma3110 model ma3110 1
- User manual 1
- Features 2
- Introduction 2
- Precautions and preparations for measurements 3
- Safety information 3
- Warnings 3
- Cautions 4
- Per iec1010 overvoltage installation category 4
- Safety symbols that are typically marked on meters and instructions 4
- Description 5
- Display icons 5
- Meter description 5
- Automatic power off 6
- Data hold 6
- Low battery indication 6
- Meter power 6
- Operation 6
- Dc and ac voltage measurements 7
- Ac current measurements 8
- Resistance measurements 9
- Continuity measurements 10
- Diode measurements 11
- Capacitance measurements 12
- Battery replacement 13
- Cleaning and storage 13
- Maintenance 13
- Specifications 13
- Ma3110 en gb_v1 12 16 14
- Specifications tested under environmental conditions of rf field strength 3v m and frequency 30mhz 14
- Copyright 2016 flir systems inc 15
- General specifications 15
- Www extech com 15
Похожие устройства
- EXTECH EX650 Инструкция по эксплуатации
- EXTECH EX650 Документация
- EXTECH EX650 Инструкция EN
- EXTECH EX650 Расширенная инструкция
- EXTECH EX810 Инструкция по эксплуатации
- EXTECH EX810 Расширенная инструкция
- EXTECH EX810 Документация
- EXTECH EX810 Инструкция EN
- EXTECH MA440 Инструкция по эксплуатации
- EXTECH MA440 Инструкция EN
- EXTECH MA440 Расширенная инструкция
- EXTECH MA443 Инструкция по эксплуатации
- EXTECH MA443 Инструкция EN
- EXTECH MA443 Расширенная инструкция
- EXTECH MA61 Инструкция по эксплуатации
- EXTECH MA61 Инструкция EN
- EXTECH MA61 Расширенная инструкция
- EXTECH MA610 Инструкция по эксплуатации
- EXTECH MA610 Расширенная инструкция
- EXTECH MA610 Инструкция EN