EXTECH MA61 [12/21] Continuity measurements
![EXTECH MA140 [12/21] Continuity measurements](/views2/1666806/page12/bgc.png)
MA44x‐en‐GB_V1.0 8/16
12
ContinuityMeasurements
WARNING:Please remove power to the circuit under test and discharge all capacitors
before taking resistance or continuity measurements. The meter will display OL if the circuit
under test is an open circuit of if the measurement exceeds the maximum range of the meter.
Do not input a voltage >30V AC or DC.
1. Turn the function switch to the Continuity
position.
2. Use the M (mode) button to select the continuity display
icon.
3. Insert the black lead banana plug into the negative (COM) jack. Insert the red test lead
banana plug into the positive (Ω) jack. See Fig. 7 above.
4. Touch the test probe tips across the circuit or wire.
5. If the resistance is < 30Ω, the meter will beep. If the resistance is > 60Ω, the meter will
not beep. If the resistance is between 30 and 60Ω, the meter will stop beeping at an
unspecified point.
FrequencyMeasurements
WARNING:Do not input voltages > 30Vrms when measuring frequency.
Turn the function switch to the Hz% position.
1. Insert the black lead banana plug into the
negative (COM) jack. Insert the red test lead
banana plug into the positive jack. See Fig. 8.
2. Touch the test probe tips across the circuit or
component.
3. Read the Frequency measurement on the
meter display.
4. For the MA443 and MA445, use the M
(mode) button to view DutyCycle%. For the
MA440 use the Hz% button to view Duty
Cycle%.
Fig.8 – Frequency Measurements
Hz %
AUTO
Содержание
- Introduction 2
- Safety 2
- Warnings 3
- Warnings identify hazardous conditions and actions that could cause bodily harm or death 3
- Cautions 4
- Safety symbols 4
- Description 5
- Display description 5
- Fig 1 meter description 5
- Meter description 5
- Control buttons 6
- Disable auto power off ma443 and ma445 7
- Operation 7
- Powering the meter 7
- Ac current measurements 8
- Fig 2 correct and incorrect aca clamping 8
- Dc current measurements ma445 9
- Fig 3 dca zero before measurement fig 4 dca measurement 9
- Ac and dc voltage measurements 10
- Fig 5 ma443 ma445 voltage test fig 6 ma440 voltage testing 10
- Fig 7 resistance and continuity measurements 11
- Resistance measurements 11
- Continuity measurements 12
- Fig 8 frequency measurements 12
- Frequency measurements 12
- Capacitance measurements 13
- Fig 9 capacitance measurements 13
- Diode test 14
- Fig 10 diode testing 14
- Fig 11 temperature measurements 15
- Temperature measurements ma443 and ma445 15
- Fig 12 non contact voltage detection 16
- Non contact voltage detector ef ncv 16
- Battery replacement 17
- Cleaning and storage 17
- Maintenance 17
- Ac current 18
- Ac voltage 18
- Dc current 18
- Dc voltage 18
- Electrical specifications 18
- Function range resolution accuracy reading ol protection 18
- Specifications 18
- Capacitance 19
- Continuity 19
- Duty cycle 19
- Frequency hz 19
- Resistance 19
- Non contact voltage detector ncv 20
- Temperature 20
- Copyright 2016 flir systems inc 21
- General specifications 21
- Www extech com 21
Похожие устройства
- EXTECH MA610 Инструкция по эксплуатации
- EXTECH MA610 Расширенная инструкция
- EXTECH MA610 Инструкция EN
- EXTECH MA620 Инструкция EN
- EXTECH MA620 Документация
- EXTECH MA620 Расширенная инструкция
- EXTECH MA620 Инструкция по эксплуатации
- EXTECH PQ3210 Инструкция по эксплуатации
- EXTECH PQ3210 Инструкция EN
- EXTECH PQ3220 Инструкция по эксплуатации
- EXTECH PQ3220 Инструкция EN
- Fluke FLK-I17XX-FLEX3K-4 Инструкция по эксплуатации
- Fluke FLK-I17XX-FLEX3K-4 Инструкция EN
- Fluke FLK-323 Инструкция по эксплуатации
- Fluke FLK-323 Инструкция EN
- Fluke FLK-323 Документация
- Fluke FLK-323 Расширенная инструкция
- Fluke FLK-324 Инструкция по эксплуатации
- Fluke FLK-324 Инструкция EN
- Fluke FLK-324 Документация